background image

page

443561208870 REV F

www.gardcolighting.com

CLEARSCAPE MAIN INSTALLATION 

CSFS / CSFM 

SF - Slip Fitter Mount

-

(Cont’d)

Note: Tenon must be 3.75" or longer. 

STEP 4:  

Fit the luminaire over the tenon. 

Using 3/16" Allen wrench, 

hand tighten (2) set screws, on the side of the tenon where 

the cord is, until tip of screws engage tenon. (Do not fully 

tighten). 

Rotate to correct horizontal aiming position. Tighten

set 

screws to 11 ft.-lbs.

when final horizontal position is set.

STEP 5: 

Make electrical connections per Electrical Connection section 
inside splice area. When complete replace splice cover and (2) 
screws removed in Step 1.  Ensure that gasket is correctly in 
place before tightening splice cover and screws. 

SF - Slip Fitter Angle Adjustment

ANGLE ADJUSTMENT 

NOTE: Angle adjustment can be made before luminaire 

installation. 
STEP 1: 
After the luminaire is installed, the angle of the luminaire 

can be adjusted approximately 90

°

up or down in 5

°

increments. 
STEP 2: 
To adjust the angle, loosen the (1) 1/2

–13 X 1.75” socket 

cap bolt located in slip fitter Arm. (Do remove bolt.) 

Loosen only enough to allow rotation on cast teeth.
STEP 3: 
Using the degree indicators, shown as a guide, rotate the 

luminaire to the desired position and retighten the bolt 

loosened in Step 2 to 47 ft.-lbs. 

Adjustment  Bolt and 

aiming indicator  lines

06/28/20211

3

Содержание Gardco CSFM

Страница 1: ... modify the luminaire Only use luminaire in its intended application and location Led products are polarity sensitive Ensure proper polarity before installation Electrostatic Discharge ESD can damage LED Personal grounding equipment must be worn during all installation and servicing of the luminaire Do not touch individual electrical components as this can cause ESD shorten LED life or impact LED ...

Страница 2: ...ositive lead to the supply dimming positive lead If Dimming is an option connect the grey dimming negative lead to the supply dimming negative lead SF Slip Fitter Mount Note Tenon must be 3 75 or longer 2 Splice Cover Screws Splice Cover Screws STEP 1 Remove 2 splice cover screws and splice cover To access wire splice area STEP 2 Route the supply wire through the tenon Secure the supply wire to ke...

Страница 3: ...ete replace splice cover and 2 screws removed in Step 1 Ensure that gasket is correctly in place before tightening splice cover and screws SF Slip Fitter Angle Adjustment ANGLE ADJUSTMENT NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the angle of the luminaire can be adjusted approximately 90 up or down in 5 increments STEP 2 To adjust the ...

Страница 4: ...llation is finished STEP 4 Replace junction box gasket and cover YK Yoke Angle Adjustment NOTE Angle adjustment can be made before luminaire installation STEP 1 After the luminaire is installed the vertical angle of the luminaire can be adjusted up or down STEP 2 To adjust the angle loosen the 2 1 2 13 X 1 25 socket head cap bolts located in yoke arm Do remove bolts Loosen only enough to allow rot...

Страница 5: ...e glass to install luminaire STEP 1 Unfasten the captive shoulder screw around the glass perimeter excluding the bottom left safety screw STEP 2 Collect all screws and remove glass gently Be sure that gasket is still seated on rib Safety cable should remain attached while servicing luminaire STEP 3 After servicing luminaire carefully rotate glass door frame up into closed position and retighten sc...

Страница 6: ...de mise à la terre pendant toute intervention d installation ou de réparation sur le luminaire Ne touchez pas aux composants électriques individuels étant donné que ceci peut causer une DES raccourcir la durée de vie des DEL ou nuire à leur rendement Certains composants internes du luminaire peuvent ne pas être réparables Aussi peu probable que ça pourrait l être si votre luminaire a besoin de rép...

Страница 7: ... de gradation d alimentation 2 Vis de couverture d épissure SF Support de montage coulissant Remarque Le tenon doit mesurer 3 75 ou plus SF Support de montage coulissant Remarque Le tenon doit mesurer 3 75 ou plus ÉTAPE 1 Retirez les 2 vis du couvercle d épissure et le couvercle d épissure Pour accéder à la zone d épissure de fil ÉTAPE 2 Acheminez le fil d alimentation à travers le tenon Fixez le ...

Страница 8: ...rcle d épissure et les 2 vis retirées à l étape 1 Assurez vous que le joint est correctement en place avant de serrer le couvercle d épissure et les vis RÉGLAGE DE L ANGLE REMARQUE Le réglage de l angle peut être effectué avant l installation du luminaire ÉTAPE 1 Une fois le luminaire installé l angle du luminaire peut être ajusté d environ 90 vers le haut ou vers le bas par incréments de 5 ÉTAPE ...

Страница 9: ... Remettez le joint et le couvercle de la boîte de jonction YK Support de joug REMARQUE Le réglage de l angle peut être effectué avant l installation du luminaire ÉTAPE 1 Une fois le luminaire installé l angle vertical du luminaire peut être ajusté vers le haut ou vers le bas ÉTAPE 2 Pour régler l angle desserrez les 2 boulons à tête creuse 1 2 13 X 1 25 situés dans le bras de la fourche Retirez le...

Страница 10: ...r étrier Il n est pas nécessaire d enlever le verre pour installer le luminaire ÉTAPE 1 Dévissez la vis à épaulement imperdable autour du périmètre du verre à l exception de la vis de sécurité en bas à gauche ÉTAPE 2 Récupérez toutes les vis et retirez délicatement le verre Assurez vous que le joint est toujours en place sur la nervure Le câble de sécurité doit rester attaché pendant l entretien d...