page
443561208870 REV F
www.gardcolighting.com
CLEARSCAPE MAIN INSTALLATION
CSFS / CSFM
SF - Slip Fitter Mount
-
(Cont’d)
Note: Tenon must be 3.75" or longer.
STEP 4:
Fit the luminaire over the tenon.
Using 3/16" Allen wrench,
hand tighten (2) set screws, on the side of the tenon where
the cord is, until tip of screws engage tenon. (Do not fully
tighten).
Rotate to correct horizontal aiming position. Tighten
set
screws to 11 ft.-lbs.
when final horizontal position is set.
STEP 5:
Make electrical connections per Electrical Connection section
inside splice area. When complete replace splice cover and (2)
screws removed in Step 1. Ensure that gasket is correctly in
place before tightening splice cover and screws.
SF - Slip Fitter Angle Adjustment
ANGLE ADJUSTMENT
NOTE: Angle adjustment can be made before luminaire
installation.
STEP 1:
After the luminaire is installed, the angle of the luminaire
can be adjusted approximately 90
°
up or down in 5
°
increments.
STEP 2:
To adjust the angle, loosen the (1) 1/2
–13 X 1.75” socket
cap bolt located in slip fitter Arm. (Do remove bolt.)
Loosen only enough to allow rotation on cast teeth.
STEP 3:
Using the degree indicators, shown as a guide, rotate the
luminaire to the desired position and retighten the bolt
loosened in Step 2 to 47 ft.-lbs.
Adjustment Bolt and
aiming indicator lines
06/28/20211
3