background image

Page 6

Doc No. DCP0000487  JH  12/7/99  rev3

Loop cables

Cable selection

Almost any single core cable (multi-strand

or solid core) can be used for the loop provided it
is of the appropriate impedance. Ideally the DC
impedance of the loop should be 1 Ohm  (<0.2
Ohm or >2 Ohm will result in a degradation in
signal). The following table gives some useful
approximations.

Use of a tri-rated cable is recommended.

This is cable with a tougher than usual jacket,
the reason being; damage will occur to the ampli-
fier if at any point the loop is grounded.

Loop cable should ideally be laid at floor

level but in certain circumstances this may not
be possible. Any large amounts of metal (eg
steel meshed reinforced concrete floors) will ab-
sorb some of the signal strength, in this case the
cable may have to be mounted in the walls.

Aluminium (suspended ceilings) being

para-magnetic should also be avoided, mounting
a loop above a aluminium suspended ceiling will
probably result in almost no coverage, turning up
the output of an amplifier would just make mat-
ters worse as it will just stress the output stage
(and minutely warm the aluminium) resulting in a
definite shortening of the life-span of the ampli-
fier.

Recommended cable gauge
PDA200

0.75 -1.0mm

2

PDA800

1.5 - 2.5mm

2

Use of cables outside the recommended
gauges may may result in damage to the unit,
or risk of fire.

Optimum cable lengths:
Cable diameter

Optimum lengths

0.75mm

2

up to 30 metres

1.0mm

2

30 - 70 metres

1.5mm

2

70 - 100 metres

2.5mm

2

100 - 165+ metres

Only use cable diameters recommened for each
unit

Speaker positioning

If a speaker is placed near or beside a loop

cable the cross-over in the speaker may pick up
the loop signal, so try to keep speakers and loop
cables as far apart as possible. Normally this
does not show up in use because loop and
speaker have the same programme material,
only where the loop has a different signal to the
speakers (e.g. stage talk back systems)will this
become an issue.

Feeder Cables

When connecting an amplifier to a loop

some distance away use a heavy gauge twisted
pair (4-6mm

2

 ). This will have a negligible

impedance, as such the amplifier will not drive
against it and the power will be fed into the loop
where it can do useful work. For the cable size of
the actual loop, follow guidelines opposite.

Test loops

We always recommend the laying of a test

loop, there is no such thing as a standard instal-
lation and sometimes only a test loop will uncover
problematic areas.

Feedback

Long lengths of unbalanced signal cable

may cause feedback when placed inside the
loop. This problem can be virtually eliminated by
using balanced signals.

Problems may occur when using standard

dynamic microphones. The coil inside may act
as a receiver and cause feedback. It is advisable
to use condenser microphones. These may re-
quire phantom powering, available on both mi-
crophone inputs.

Other sources of feedback are coils in other

equipment that is linked to the induction loop
system, for example guitar pickups.

Loop cable class

A loop cable is classed as a 2A cable under

IEEE 16

th

 Edition wiring regulations. As such it

must be sited a minimum of 600mm away from
telephone, mains and control cables.

Loop cables

Содержание PDA200

Страница 1: ...r efficiency and to correct the phase prob lems created by driving an inductor The PDA 200 and 800 have a wide range companding system to give a con stant output level for a varying input level This is particularly useful when dealing with fixed microphones used by people moving within the space around it the compander compensates for these changes in level A Compressor output is available to conn...

Страница 2: ...EARTH symbol mark GREEN mark GREEN AND YELLOW mark Blue N mark BLACK mark BLUE mark Brown L mark RED mark BROWN mark Caution To prevent electric shock do not remove the cover Upon receipt of the amplifier shipment please inspect for any damage incurred in transit If damage is found please notify your local repre sentative and the transport company immedi ately State date nature of damage and wheth...

Страница 3: ...plifier The peak line level of this signal should be approximately 1V 4 Ensure input levels controls and drive control are fully anti clockwise 5 Increase the input level controls until the limit LED is just flashing This indicates that the dynamic range processor is receiving a signal of the correct level The compression ratio is fixed at a ratio of 20 1 If you are using both inputs the level con...

Страница 4: ...ntical outputs from the compressor This facility has been designed to allow recording of the compressed signal Pins 1 and 4 of the connector are internally linked and carry the same signal pin1 signal out pin4 signal out pin2 ground The X talk connections allow a a PDA in duction loop amplifier to be cross connected to a MA75 MA150 mixer amplifier so that all 8 inputs are mixed Both sets of contro...

Страница 5: ...the same level as the receiver Vertical displacement If the loop is significantly higher or lower more than one to two metres than the receiver then the peak current required will be slightly higher Peak current calculation Refer to the current width graph to estab lish the required peak current The width of the loop is shown on the x axis The peak current is shown vertically on the y axis This is...

Страница 6: ... metres Only use cable diameters recommened for each unit Speaker positioning If a speaker is placed near or beside a loop cable the cross over in the speaker may pick up the loop signal so try to keep speakers and loop cables as far apart as possible Normally this does not show up in use because loop and speaker have the same programme material only where the loop has a different signal to the sp...

Страница 7: ... Note For a two storey building the same loop position on different floors is also 90 degrees out of phase Non rectangular rooms Layout as per a basic pattern and step back the prongs to the shape of the room Each pattern should be considered as a many pronged fork The pattern should be spaced approx 2m from nearest wall next pattern prongs of the fork should be spaced approx 2m apart and should b...

Страница 8: ...amic range 90 dB Noise 86 dB CMRR 84 dB Input level control Line ì to 6 dB Mic ì to 66 dB X Talk 5 Pin DIN Link to PDA 200 800 or MA75 Compressor out 5 Pin DIN 300 mV Mains voltage 230 V AC 20 Power Consumption PDA200 80 VA PDA800 200 VA Dimensions Width 305 mm Height 72 mm Length 200 mm Specification PDA 800 Output Drive current Max peak 12 A EBU PPM 10 A Sine 1KHz 4 A RMS Loop coverage 400m 2 Lo...

Отзывы: