Doc No. DCP0000487 JH 12/7/99 rev3
Output connections
Loop output
The output is via two 30A 4mm terminal
posts. Connection can be made by way of tails or
4mm plugs. Tails are recommended as they are
very unlikely to be pulled out.
WARNING: The PDA amplifiers are capa-
ble of producing short term peaks of twice their
rated current.
Compressor output
The compressor out connector on the rear
of the case provides two identical outputs from
the compressor. This facility has been designed
to allow recording of the compressed signal.
Pins 1 and 4 of the connector are internally
linked and carry the same signal.
pin1
signal out
pin4
signal out
pin2
ground
The X-talk connections allow a a PDA in-
duction loop amplifier to be cross-connected to a
MA75 \ MA150 mixer amplifier so that all 8
inputs are mixed. Both sets of controls will work
independently of each other.
If the mute connection is used the PDA
induction loop amplifier inputs will be muted
when priority on the MA range amplifier is oper-
ated.
(see MA range manual for more detail)
X-talk