9
ENGLISH
SKSFD3614P – 36” INTEGRATED FRENCH DOOR REFRIGERATOR
NOTE
R
mm) depth adjacent cabinets.
Proud – With a 24" (610 mm) depth cutout, the front face of the freezer extends approximately
9
0
•
A
0
all sides and the top of the cutout opening. The shaded area will be visible after installation.
ELECTRICAL
A 230-240 V, 50 Hz, 15 or 20 amp power supply is required. An individual properly grounded
branch circuit or circuit breaker must be used in case of requiring disconnect after installation.
Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
WATER LINE
A cold water supply is required for automatic icemaker operation.
The water pressure must be between 20 and 120 psi.
Tubing should be long enough to extend to the front of the freezer. Allow enough tubing to
accommodate a bend leading into the water line connection.
Install a shut-off valve between the icemaker water valve and the cold water supply in the home.
CUTOUT DIMENSIONS – FLUSH OR PROUD INSTALLATION
1 3/8
"
(35mm)
Electrical location
is not available
1 3/8
"
(35mm)
Electrical location
is not available
36"
(914 mm)
84"
(2134 mm)
5"
(127 mm)
electrical
location
4"
(102 mm)
water
location
4"
(102 mm)
finished
return*
25"
(635 mm)
min. depth
flush install
24"
(610 mm)
min. depth
proud install
finished width