3
PRESSURE BALANCE VALVE
INSTALLATION
1. Shut o� the
water supply
.
1-1/2”
3.8 cm
finished
wall
finished
wall
3
-
3/
8
”
-6
”
6
”
1
1
2
2
Thin Wall Installation
Thick Wall Installation
2. Verify that the hole sizes and position of the holes
in the wall are correct. The shower outlet hole should
be 1-1/4” diameter. The recommended valve depth
to the �nished wall is 1-1/2”. Ensure that the valve
body cover is �ush with the �nished exterior surface
of the wall. Position the valve body correctly in the wall
with the side marked “UP” pointed upward.
3a.
Thin Wall Installation:
Are usually built up with
materials such as �berglass tub surrounds and will be
the main source of support for the valve. The plaster
guard (1) remains attached to the valve.
3b.
Thick Wall Installation:
Are usually built up with
materials such as cement board, drywall, tile, etc. The
plaster guard (1) is positioned so that it is �ush with the
�nished wall. This ensures that the valve will be at the
correct position to accept the trim. The depth for the
valve body (2) in wall is measured from the center of the
shower outlet to the �nished wall surface. The accept
-
ed depth distance is 1-1/2”
4. Rem
o
ve the plaster guard (1) f
r
om the body (2).
1
2
1
2
5. Fasten the body assembly (1) to cross brace with
moutning screws (2).
Note:
Be sure to position the body (1) correctly in the
wall, with the side marked “UP” facing upward.
G L E N L E Y P R E S S U R E B A L A N C E
SHOWER HEAD AND BODY SPRAYS
SKU: 925471