Ground the Media Converter

1. 

 This equipment must be grounded. Never defeat the 

ground conductor or operate the equipment in the 

absence of a suitably installed ground conductor. 

Contact the appropriate electrical inspection 

authority or an electrician if you are uncertain that 

suitable grounding is available.

2.

 Attach a lug (not provided) to a #12 AWG (PoE 

converter) or #18 AWG (non-PoE converter) 

minimum grounding wire (not provided), and connect 

it to the grounding point on the converter rear panel. 

Then connect the other end of the wire to ground. 

Caution: 

The earth connection must not be 

removed unless all supply connections have 

been disconnected. 

Note:

  The device must be installed in a 

restricted access location. It should have a 

separate protective earthing terminal on the 

chassis that must be permanently connected 

to earth to adequately ground the chassis and 

protect the operator from electrical hazards.

!

Connect Power

1. 

Insert the positive and negative wires into the PWR1 

(+,-) and PWR2 (+,-) on the terminal block connector.

2.

 Tighten the screws to prevent the wires from 

loosening.

PWR 1

PWR 2

Содержание I-1100 Series

Страница 1: ...Quick Start Guide I 1100 Series Media Converters ...

Страница 2: ...ments of a Class 1 Laser Product and are inherently eye safe in normal operation However you should never look directly at a transmit port when it is powered on Warning When selecting a fiber SFP device considering safety please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product You must also use an approved Laser Cl...

Страница 3: ...Media Converter 2 Part Number RJ 45 Ports PoE Ports Fiber Ports MI10010 2 Gigabit 2 2 SFP MI10020 2 Gigabit N A 2 SFP MI10030 2 10 100 2 SC MM MI10040 2 10 100 2 SC MM MI10050 2 10 100 N A SC MM MI10060 2 10 100 N A SC MM Note Additional documentation can be obtained from www signamax com 1 Screw the DIN Rail bracket to the media converter ...

Страница 4: ...www signamax com 3 3 Pull down the DIN Rail bracket to the DIN Rail track and check if it is mounted tightly on the DIN Rail track 2 Insert the top of the DIN Rail bracket to the DIN Rail track ...

Страница 5: ...t provided and connect it to the grounding point on the converter rear panel Then connect the other end of the wire to ground Caution The earth connection must not be removed unless all supply connections have been disconnected Note The device must be installed in a restricted access location It should have a separate protective earthing terminal on the chassis that must be permanently connected t...

Страница 6: ...e transceiver ports The following transceivers are supported 1000BASE SX 065 79SXMG 1000BASE LX 065 79LXMG 1000BASE ZX 065 79ZXMG 1000BASE LHX 065 79LXEDMG 3 As connections are made check the port status LEDs to be sure the links are valid See the LED description table on the next page Verify Media Converter Operation 1 Verify basic converter operation by checking the system LEDs When operating no...

Страница 7: ...cted or the media converter has failed LINK ON Port has a valid link BLINKING Port has network activity OFF The link is down PoE ON A PoE device is connected and delivered PoE power BLINKING PoE Error short circuit or current overload OFF Doesn t deliver PoE power MODE ON Port has a valid 1000 Mbps link OFF Port has a valid 10 100 Mbps link ...

Страница 8: ...999 NW 159th Dr Miami FL 33169 800 446 2377 305 944 7710 CONNECT WITH US www signamax com ...

Отзывы: