www.signamax.com
I-100 SERIES
QUICK START GUIDE
4
Ground the Switch
1.
This equipment must be grounded. Never defeat
the ground conductor or operate the equipment
in the absence of a suitably installed ground
conductor. Contact the appropriate electrical
inspection authority or an electrician if you are
uncertain that suitable grounding is available.
2.
Attach a lug (not provided) to a #12 AWG (PoE
switch) or #18 AWG (non-PoE switch) minimum
grounding wire (not provided), and connect it to
the grounding point on the switch rear panel. Then
connect the other end of the wire to ground.
Caution:
The earth connection must not be
removed unless all supply connections have
been disconnected.
Note:
The device must be installed in a
restricted access location. It should have a
separate protective earthing terminal on the
chassis that must be permanently connected
to earth to adequately ground the chassis and
protect the operator from electrical hazards.
!
Connect Power
1.
Insert the positive and negative wires into the PWR1
(+,-) and PWR2 (+,-) on the terminal block connector.
2.
Tighten the screws to prevent the wires from
loosening.
PWR 2
PWR 1