Ratelimit Egress [<portlist>] [enable|disable] [<rate>]   

 
Description: 
Set or show the egress configuration. 
 
[<portlist>]              : Port list (default: All ports). 
[enable|disable]      : Enable or disable egress. 
[<rate>]                      : Disable or set leaky bucket rate in Kbit/s 
                                          [128/256/512/1024/2048/3072k] 
                                          (default: Show egress rate). 
 

 

Ratelimit Ingress[<portlist>] [enable|disable] [<rate>] 

 

Description: 
Set or show the ingress configuration. 
 
[<portlist>]              : Port list (default: All ports). 
[enable|disable]      : Enable or disable ingress. 
[<rate>]                      : Disable or set leaky bucket rate in Kbit/s 
                                          [128/256/512/1024/2048/3072k] 
                                          (default: Show ingress rate). 

 

Содержание 065-7942

Страница 1: ...Signamax Connectivity Systems __________________________________________ 065 7942 1 Signamax Connectivity Systems 24 Port Gigabit Web Smart Switch With 4 Combo Slots Model 065 7942 User Manual...

Страница 2: ...ned to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Страница 3: ...STALLATION 8 DESKTOP INSTALLATION 8 RACK INSTALLATION 8 INSTALLING NETWORK CABLES 8 DESCRIPTION OF SWITCH FUNCTIONS 10 JUMBO FRAME 10 FLOW CONTROL AND BACKPRESSURE 10 MIRROR 10 VLAN 10 TRUNK AGGREGATI...

Страница 4: ...RING COMMANDS 31 COMMAND DESCRIPTION 32 System Commands 32 Console Commands 33 Port Commands 34 VLAN Commands 36 Aggregation Commands 38 QoS Commands 39 Mirror Commands 40 IP Commands 41 SNMP Commands...

Страница 5: ...ports the Switch offers 4 fiber ports slots that can be used in the place of the last 4 copper ports these are interchangeable or combo ports These mini GBIC slots offer the option of a long distance...

Страница 6: ...ance Supports firmware upgrade SNMP FCC Class A CE VCCI RoHS compliant The Front Panel The front panel features all the LED indicators and ports Device LED LED Status Operation Steady Green The switch...

Страница 7: ...nd disables the copper port Restore Default Button You can use this button to reset the switch or restore it to its factory default settings To reset the switch press the button once To restore factor...

Страница 8: ...ation in cases where many networking devices have to be installed in the same area The Switch is supplied with brackets and screws for rack mounting purposes 1 Disconnect all cables from the Switch be...

Страница 9: ...Speed Wiring 10Mbps Category 3 4 5 Utp STP 100Mbps Category 5 UTP STP 10 100 1000Mbps copper 1000Mbps Category 5 5e UTP STP 1000Mbps Fiber Mini GBIC required 1000Mbps The cable type differs according...

Страница 10: ...ives all the packets and hence is able to monitor the traffic through the specified port VLAN This Switch supports Virtual LAN which means the network can be segmented into groups to reduce collisions...

Страница 11: ...guration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The Function arrow and ctrl keys act as...

Страница 12: ..._____________________________ 065 7942 12 Homepage After successful log in the SYSTEM Configuration page appears this is also the Homepage You can click on the hyperlinks on the left side of each page...

Страница 13: ...Subnet Mask of the switch Gateway Set up the Gateway of the switch Management VLAN The VLAN group that is allowed to access the WEB based management interface User Name The Log in name Default admin...

Страница 14: ...Select a speed for this port Auto Speed enables auto negotiation Disable stops the port from functioning Flow Control Mark the checkbox to enable the FDX Flow Control or unmark to disable Max Frame l...

Страница 15: ...ase follow the instructions to configure To add new VLAN groups 1 Fill in a VLAN ID from 2 to 4094 in the VLAN Port column 2 Select the ports for each VLAN group 3 Click the Apply button to execute To...

Страница 16: ...gged Tagged Packet Frames In Packet Frames Out Packet Frames In Packet Frames Out Untagged Untagged Untagged Tagged PVID Tagged Untagged Tagged VID Tagged VID Pri tagged Untagged Pri tagged Tagged PVI...

Страница 17: ..._________________________________________ 065 7942 17 SMAC modes to decide the path of the packets Note 1 Settings in VLAN Port Aggregation and Mirror are co dependent Please make sure that the settin...

Страница 18: ...tems __________________________________________ 065 7942 18 Quality of Service QoS enhances communication quality by giving precedence to certain classes of packets This switch provides port based tag...

Страница 19: ...h port as having a high or low priority To assign a priority level to each port 1 Select Port in the Mode column for those ports that are going to function as part of port based QoS Click the Apply bu...

Страница 20: ...g based QoS 1 Select Tagged in the Mode column for those ports that are going to perform tag based QoS Click the Apply button 2 Click the Tag priority button The Tag Priority Setting page shows up 3 S...

Страница 21: ...owing Bit 0 Delay Bit 1 Throughput Bit 3 Reliability 0 Normal 0 Normal 0 Normal 1 Low 1 High 1 High Note The Switch distinguishes packets with DSCP precedence 000 routine only To configure DSCP based...

Страница 22: ...he destination port It allows administrators to analyze and monitor the traffic of the monitored ports Mirror Configuration 1 Select those ports that are going to be monitored by marking the checkboxe...

Страница 23: ...ate Limit page allows users to limit the bandwidth for each port and configure the rules for Storm Control which limits the flow of broadcast and multicast To perform storm control 1 Click on each dro...

Страница 24: ...s device to be managed via SNMP 1 Select enable in the drop menu 2 Specify a trap IP A trap IP is the destination port for sending trap information which is usually the IP address of network administr...

Страница 25: ...Note The discovery tool lists a maximum of 16 devices respectively for auto and manual modes Auto Search 1 Click the Apply button to start 2 The devices being found are listed below 3 Click the IP add...

Страница 26: ...h port You may click the Clear button to clean all statistics or click the Refresh button to renew the statistics Detailed Statistics The Detailed Statistics is provided for users to see the detailed...

Страница 27: ...e Factory Default To restore the factory default settings click the Yes button Note The IP address of the device will also be reconfigured to the factory default setting which is 192 168 0 254 Smart B...

Страница 28: ...e 1 Click the Browse button 2 Locate the firmware file 3 Click the Upload button to execute Note This new firmware is going to be applied on the remaining flash that you have NOT selected in Smart Boo...

Страница 29: ...on Cable Connections RJ 45 10BASE T Category 3 4 5 UTP STP RJ 45 100BASE TX Category 5 UTP STP RJ 45 1000BASE T Category 5 5e or enhanced UTP STP Fiber depends on Mini GBIC types Network Data Rate 10...

Страница 30: ...ld be started in the following configuration 1 Data rate 115200 baud 2 Data format 8 data bits 1 stop bit and no parity 3 Flow control none 4 Click the property icon select settings make sure that The...

Страница 31: ...Logout commands Press or help to get help The help depends on the context where you are in the program At top level a list of command groups will be shown At group level a list of the command syntaxes...

Страница 32: ...password System Systemname name System Reboot System Configuration all Syntax System Configuration all Description Show system name username password software version and management MAC address Option...

Страница 33: ...l Console Configuration Console Timeout timeout Console Prompt prompt string Console Configuration Description Show configured console prompt and timeout Console Timeout timeout Description Set or sho...

Страница 34: ...uplex mode flow control mode and admin state for the port portlist Port list Default All ports Port Mode portlist mode Description Set or show the speed and duplex mode for the port portlist Port list...

Страница 35: ...tion Set or show the maximum frame size in bytes including FCS for frames received on the port Tagged frames are allowed to be 4 bytes longer than the maximum frame size Use the reset option to return...

Страница 36: ...onfiguration portlist Description Show the VLAN egress mode port VLAN ID and accepted frame type for the port and the permanently stored VLAN table portlist Port list default All ports VLAN Add vidlis...

Страница 37: ...d default Show egress tag setting VLAN PVID portlist vid none Description Set or show the port VLAN ID Untagged frames received on the port will be classified to this VLAN ID Frames classified to this...

Страница 38: ...tion groups and the aggregation mode Aggr Delete portlist Description Delete link aggregation group portlist Port list Aggregations including any of the ports will be deleted Aggr Lookup portlist Desc...

Страница 39: ...ortlist Port list default All ports tag port diffserv Enable tag port or IP differentiated services class of service for the port default Show mode QoS Port portlist class Description Set or show the...

Страница 40: ...ror Port port Mirror Source portlist enable disable Mirror Configuration Description Show the mirror destination port and mirror mode for source ports Mirror Port port Description Set or show the mirr...

Страница 41: ...anagement Description Activate or deactivate the Web management enable disable Enable disable Web management default Show Web management SNMP Commands Commands at SNMP level SNMP Configuration SNMP Co...

Страница 42: ...bucket rate in Kbit s 128 256 512 1024 2048 3072K default Show rate Ratelimit Configuration Description Show the Ratelimit setting Ratelimit Setup traffic type option Description Set or show the rate...

Страница 43: ...enable disable Enable or disable egress rate Disable or set leaky bucket rate in Kbit s 128 256 512 1024 2048 3072k default Show egress rate Ratelimit Ingress portlist enable disable rate Description...

Отзывы: