15 Administration
81
Onaccess cold start:
Enable or disable to trigger an e-mail alarm when the switch is booted
up by turning on the power.
Onaccess warm start:
Enable or disable to trigger an e-mail alarm when the switch is
restarted without turning off power.
Auth failure:
Enable or disable to trigger an e-mail alarm when it fails to login to the switch
due to incorrect username or password.
RecoverRing II™ topology change:
Enable or disable to trigger an e-mail alarm when the
RecoverRing II™ link status has been changed, for example, the RecoverRing II™ port is
down.
RMON event log:
Enable or disable to trigger an e-mail alarm when an event occurs
mentioned in
14 RMON
of this manual.
15.5.2 Port Event
This page sets port event alarm configuration, including
Port
,
Alarm Type
,
Traffic Overload
,
Traffic Threshold
and
Traffic Duration
.
Port:
Specify the port selected for port event configuration
Alarm Type:
If it is enabled, there are three alarm types for the event: Link Up, Link Down,
and Up & Down.
Traffic Overload:
It means that the port traffic exceeds Traffic Threshold during a statistics
time of Traffic Duration.
Traffic Threshold:
The threshold for port traffic (in percentage of the port speed).
Traffic Duration:
The statistics duration time for calculating port traffic.
Note:
Traffic Overload
,
Traffic Threshold
and
Traffic Duration
are interrelated. When
Traffic
Overload
is enabled,
Traffic Threshold
shall be set with a number between 1 and 99, and
Traffic Duration
shall be no less than 10 seconds.