 065-1163T RS-232/422/485 to 10/100BaseT/TX Media Converter

 

Installation

 

1

 

 

I

NTRODUCTION

Product Overview 

Thank you for  selecting  the  Signamax

  RS-232/422/485 to

10/100BaseT/TX Media Converter.  This converter is 
designed to provide a RS-232/422/485 point-to-point 
connection over  twisted pair cable where the connected 
devices employ a RS-232/422/485 interface.  It enables serial 
devices such as CNCs and PLCs to connect to an existing 
Ethernet/ Fast Ethernet network, thereby permitting the same 
cabling plant to support a convergent, multi-functional network 
solution. 

This single port converter features complete Ethernet and 
TCP/IP support for 100 Mbps data rates over fiber, making it 
easy  for milling machines, measurement instruments and 
other serial devices to migrate to network-based automation. 
Additionally, by deploying the media converter, users can 
install the device as a standalone solution or in a Signamax

065-1180 or 065-1185  chassis for a rack mount system, 
thereby retaining investments made in the existing serial 
equipment and software. 

 

 

 

 

 

Содержание 065-1163T

Страница 1: ...SIGNAMAX Networks 065 1180 FiberPack Media Converter Rack Mount Chassis Signamax Connectivity Systems RS 232 422 485 to 10 100BaseT TX Media Converter Model 065 1163T U S E R S G U I D E ...

Страница 2: ...Signamax Connectivity Systems RS 232 422 485 to 10 100BaseT TX Media Converter Model 065 1163T User s Guide ...

Страница 3: ...nment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense CE Mark Warning Thi...

Страница 4: ...ned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged Ethernet is a trademark of Xerox Corporation Microsoft Windows is a trademark of Microsoft Corporation SignamaxTM Connectivity Systems is a trademark of Advanced Electronic Support Products Inc ...

Страница 5: ...CKAGE CONTENTS 5 CHAPTER 2 INSTALLATION 6 DTE DCE SWITCH SETTING 7 CONNECTION TO DATA TERMINAL EQUIPMENT DTE 7 CONNECTION TO DATA COMMUNICATION EQUIPMENT DCE 7 CHAPTER 3 LED INDICATORS 8 LED INDICATORS 8 CHAPTER 4 DIP SWITCHES 9 DIP SWITCHES 9 APPENDIX A RS 422 485 CONNECTOR PIN ASSIGNMENT 10 APPENDIX B APPLICATION EXAMPLE 11 APPENDIX C CONTACT INFORMATION 12 ...

Страница 6: ...to an existing Ethernet Fast Ethernet network thereby permitting the same cabling plant to support a convergent multi functional network solution This single port converter features complete Ethernet and TCP IP support for 100 Mbps data rates over fiber making it easy for milling machines measurement instruments and other serial devices to migrate to network based automation Additionally by deploy...

Страница 7: ...onverter Introduction 2 Product Illustrations RS 232 422 485 to 10 100Base TX Converter A B C D E F Panel View Key A RJ45 10 100BaseT TX Ethernet port B Port LEDs C Female DB9 serial port D DIP switches E Power LED F Power input Front Panel View Rear Panel View ...

Страница 8: ...f duplex asynchronous serial data transmission RS 485 Supports serial port asynchronous data rates up to 115 2 Kbps Extended distances up to 1 2 km 24 AWG using RS 422 485 Auto detecting 10 100 Mbps Ethernet interface 3 in 1 RS 232 422 485 serial interfaces Terminator feature improves signal quality and distance LEDs for at a glance device status Stand alone or chassis installation External power ...

Страница 9: ...orts 1x UTP 100 120ohm RJ 45 type 1x 9 pin serial connector D sub female Data Rates UTP 10 or 100 Mbps Serial 50 115 2 kbps asynchronous Max Distance UTP 100 meters Cat 3 4 5 Serial 1 200 meters RS 422 RS 485 24 AWG 15 meters RS 232 Signals RS 232 TxD RxD CTS RTS DTR DSR RI DCD GND RS 422 TxD RxD GND RS 485 Data Data GND Configuration Parity None even odd Data bits 7 8 Stop bits 1 2 only None pari...

Страница 10: ... 2 wire DIP 7 Enables disables termination TMR Power AC power adapter 12V DC 0 8A Frequency 47Hz to 63Hz Environment Operating Temperature 32 F to 131 F 0 C to 55 C Relative Humidity 10 to 80 non condensing Non Operating Storage Temperature 13 F to 158 F 25 C to 70 C Relative Humidity 5 to 90 non condensing Emissions FCC Part 15 of Class A CE approved Dimensions 2 9 x 4 3 x 0 9 inches W x D x H 73...

Страница 11: ...n 6 Package Contents The Signamax 065 1163T RS 232 422 485 to 10 100BaseT TX converter package includes One media converter unit One power adapter please check connector type and input power specification Four self adhesive pads Two screws for wall mount installation User s Manual ...

Страница 12: ... Female Connector Pin Assignment Serial Connection Connection to DTE Connection to DCE Ethernet Connection DB9 Female Connector Pin Assignment Pin RS 232 Full duplex RS 422 485 4 wire Full duplex RS 485 2 wire Half duplex Signal Direction 1 DCD OUT 2 RX RX DATA B IN 3 TX TX OUT 4 DTR IN 5 GND GND GND 6 DSR OUT 7 RTS RX DATA A IN 8 CTS TX OUT 9 RI IN NOTE Bi directional RS 485 BUS line ...

Страница 13: ...al Connection ON RS 232 Console OFF Data Communication NOTE Default factory setting is ON position WARNING To avoid incorrect connection please review your DTE or DCE s connector and the converter s connector pin definition before installation For some RS 422 485 devices which may not be designed to provide DB 9 connection please ignore the DTE DCE mode installation procedure and check the pin def...

Страница 14: ...below DIP 2 DIP 3 DIP 4 RS 232 ON OFF OFF 4 wire RS 422 485 OFF ON OFF 2 wire RS 485 OFF OFF ON 3 Prepare TIA EIA 574 compliant cross over shielded cables with DB 9 connectors 4 Connect male DB 9 connector at one end of the cable to the converter s female DB 9 connector 5 Connect male or female DB 9 connector at other end of the cable to the DTE s male or female DB 9 connector 6 Once the device is...

Страница 15: ...FF OFF 4 wire RS 422 485 OFF ON OFF 2 wire RS 485 OFF OFF ON 3 Set DIP switch 7 to the OFF position for RS 232 application ON position for RS 422 485 applications 4 Prepare TIA EIA 574 compliant cross over shielded cables with DB 9 connectors see Appendix A for further details 5 Connect male DB 9 connector at one end of the cable to the converter s female DB 9 connector 6 Connect male or female DB...

Страница 16: ...RS 232 ON OFF OFF 4 wire RS 422 485 OFF ON OFF 2 wire RS 485 OFF OFF ON 3 Set DIP switch 7 to the OFF position for RS 232 applications ON position RS 422 485 applications 4 Prepare TIA EIA 574 compliant straight through shielded cables with DB 9 connectors see Appendix A and Appendix B for further details 5 Connect the male DB 9 connector at one end of the cable to the converter s female DB 9 conn...

Страница 17: ...n auto sensing auto negotiating RJ 45 Ethernet port Simply insert one end of a Category 3 4 5 5e type twisted pair cable into the media converter s RJ 45 port and the other end into a hub switch or computer s Ethernet card NOTE The RJ 45 port accepts both straight through and cross over Ethernet cables without the need to reconfigure the port ...

Страница 18: ...k Their functions are as follows Unit LED PWR Green light indicates normal operation Port LEDs LNK ACT Flashing green light indicates that the converter is receiving link pulses from compliant devices ACT Green light indicates that the converter is transmitting or receiving data from the RS 232 422 485 interface POST Green light indicates that the converter s Power On Self Test was successful 100 ...

Страница 19: ...will describe the CLI or Menu driven via Telnet configuration Console Port The media converter is accessible via a terminal emulator attached to the RS 232 console port After completing the steps outlined to connect the devices see Connection to Data Terminal Equipment in the previous chapter proceed with the directions below to log in to the management facility using a HyperTerminal The converter...

Страница 20: ...the following command line to change the device IP address in CLI mode where xxx s represent values between 0 and 254 and the user should enter their own IP address in this form set eth0 ip xxx xxx xxx xxx 2 After entering the new IP address The system will confirm whether the operation is successful NOTE Copy the new address down on a piece of paper You will need the address when you are going to...

Страница 21: ... since there is no default value and press ENTER to proceed 5 Select either the CLI User Interface or the Menu driven Interface option by using the associated number key or using the TAB key and pressing ENTER A Main Menu screen appears Main Menu Configuration Options The figure below shows the Main Menu screen From this screen the configuration options available provide the user the ability to qu...

Страница 22: ...nformation Menu From this menu the user can view some system related information and a default IP address The user should set up the appropriate IP address subnet mask and Gateway for his own network After entering a new IP address Telnet and data communication will be based on the new address ...

Страница 23: ...namic Host Configuration Protocol allows the converter to obtain an IP address from the DHCP server automatically NOTE A DHCP server must exist and be available in your local network prior to enabling the DHCP client RS232 Transfer and Serial Port Configuration Menu The RS232 Transfer menu is applicable to all RS 232 ...

Страница 24: ...ocess involves the server waiting for a connection service request sent by the client During this process the default setting is AUTO mode wherein the system will determine which end is the server and which end is the client automatically NOTE The server and client can be designated manually if necessary WARNING Changes to the settings are saved to a system flash memory and do NOT take effect unti...

Страница 25: ...c passing through the media converter Set the idle time value between 30 and 3600 seconds and when this time has been reached the connection will be terminated automatically Under the Serial Port Configuration heading the field Operation Mode is a read only value indicating one of the following modes Console RS 232 RS 422 or RS 485 The mode is based on the DIP switches setting found on the rear pa...

Страница 26: ...rovides at a glance system status information TFTP Firmware Upgrade Menu From this menu the user can upgrade the existing firmware to newer firmware available from a TFTP server Simply enter the file name of the updated firmware in the file name field and enter the IP address of the TFTP server in the IP address field to perform the upgrade ...

Страница 27: ...factory default settings to the converter From the Main Menu highlight the Load System Default field and hit the ENTER key to execute System Restart The System Restart allows a user to perform a warm restart and validate newly saved configuration to the media converter From the Main Menu highlight the System Restart field and hit the ENTER key to reset the unit ...

Страница 28: ...l IP address It is important to do this so that the converter doesn t conflict with other devices with the same defaults NOTE Prior to following the instructions listed below for Remote Computer Login ensure that a serial cable connection between the media converter and remote workstation exists Remote Computer Login 1 The default Login name is admin with no preset password After successful login ...

Страница 29: ...ication connection WARNING IP addresses are unique If an address isn t available please contact the appropriate authorities to apply for one 3 After you log into the system you will see a welcome message on screen 4 Press ENTER and on the following screen type the default username admin leave the password field blank since there is no default value and press ENTER to proceed 5 Select the CLI User ...

Страница 30: ...ommands and explanations Command Definitions backup Use this command to save configuration settings to file exit Type exit or logout and press ENTER to quit the program help To access help commands list ping Type ping followed by a space and then the IP address of the device to send a test signal If a response is received then the device is connected To view a full list of ping options type ping a...

Страница 31: ...th a space set admin follow the prompts to change user name and password set cfg the command is for factory setting use set eth0 ip new IP address network mask new network mask gateway new gateway Use this command to set new addresses set idle time in seconds set automatic logout when the program or communication is idle set xfer the command is for RS232 configuration and data communication settin...

Страница 32: ...rial port flow Set flow control type for serial port statistics Clear statistics upgrade Reloads configuration file or upgrades run time firmware upgrade config Use this command to reload previously saved configurations For this operation to be successful type in the IP address and filename accurately upgrade firmware Use this command to load new versions of software for this console For example u...

Страница 33: ...S 232 DTE DB9 Female PC COM1 DTE DB9 Male PIN 1 PIN 1 PIN 2 PIN 3 PIN 3 PIN 2 PIN 4 PIN 6 PIN 5 Ground PIN 5 PIN 6 PIN 4 PIN 7 PIN 8 PIN 8 PIN 7 PIN 9 PIN 9 Male to Male Wire DTE DCE Converter DB9 Female DCE Device DB9 Female PIN 1 PIN 1 PIN 2 PIN 3 PIN 3 PIN 2 PIN 4 PIN 6 PIN 5 Ground PIN 5 PIN 6 PIN 4 PIN 7 PIN 8 PIN 8 PIN 7 PIN 9 PIN 9 ...

Страница 34: ...9 B APPENDIX B RS 422 485 4 Wire Definition Converter DB9 Female RS 422 485 Device PIN 1 PIN 2 A RX PIN 3 B TX PIN 4 PIN 5 PIN 6 PIN 7 C RX PIN 8 D TX PIN 9 RS 485 2 Wire Definition Converter DB9 Female RS 422 485 Device PIN 1 PIN 2 1 B PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 2 A PIN 8 PIN 9 ...

Страница 35: ...Signamax 065 1163T RS 232 422 485 to 10 100BaseT TX Media Converter Appendix C 30 C APPENDIX C Application Examples DTE to DTE DTE to DCE ...

Страница 36: ... SWEDEN Phone 46 0 293 228 88 Fax 46 0 293 228 89 Phone 49 81 35 9303 0 Http www aesp se E mail info aesp se LANSE 3 Play AS NORWAY Telefon 22 80 19 00 Ole Deviks vei 6 0666 Oslo Postboks 406 Økern 0513 Oslo Norway Phone 47 22 80 1900 Fax 47 22 80 1901 Http www lanse no E mail lanse lanse no AESP Russia RUSSIA Kronshtadtsky Blv 125499 Moscow Russia Phone 7 095 456 0704 Phone 7 095 456 0344 Fax 7 0...

Отзывы: