Configuration
26
reset:
Type
reset config
and press
ENTER
to load
factory default settings, or type
reset system
and
press
ENTER
to restart the system.
show:
Type
show
to display a full list of view commands.
set:
To configure the management console, type the
commands below, followed by the
ENTER
key.
**NOT E: Separate each port of the command line with a space.
set admin
- follow the prompts to change user
name and password
set cfg
– the command is for factory setting use
set eth0 ip
(new IP address)
network mask
(new network mask)
gateway
(new gateway).
Use this command to set new addresses.
set idle
(time in seconds)
–
set automatic logout
when the program or communication is idle
set xfer
– the command is for RS232
configuration and data communication setting.
The command syntax is as shown below:
set xfer [arg_1 data_1] [arg_2 data_2] ...
[arg_n data_n]
[Argument List]
idle........... Set idle time of serial port
type… … … Set operation type (AUTO, SERVER
or CLIENT)
remote...... Set remote IP address