background image

SSPT724A Timer Quick Start Guide 

Open timer enclosure and remove mounting parts and instructions. 

When ready to program the timer, plug in timer to 120 Volt Ac power receptacle 

Press the SET button to reach the “Press Enter to Set Time” then press Enter 

Pressing Enter begins the curser scrolling the positions available for entry. 

Set the Date and the current time—NOTE: All times need to be expressed in 
Military 24 hour time (i.e. 3PM is 15:00) 

Press the Set button to reach the “Press Enter to Set BK (Block)” then press Enter 

Pressing Enter begins the curser scrolling the positions available for entry. 

Set the Block for the days of the week you need the timer to sound the horn (i.e. 
Monday and Friday for Monday through Friday—make sure your first day begins 
your week and follows to the end of your week—do not set the Block for Saturday 
and Sunday for instance because that is ONLY Saturday and Sunday. A full 7 days 
should be Monday and (through) Sunday. Time=DS simply allows for Daylights 
saving time adjustment and can be left at DS if desired. 

Press the Set button to reach the “Press Enter to Set Evnt (Event)” then press Enter 

Pressing Enter begins the curser scrolling the positions available for entry. 

Event numbers begin at 01 and move up during subsequent event programming. 

The entry position to the right of the ^ MUST be set for PL (pulse) for all events 
you set. 

The position further to the right is the duration the horn will sound—you can set 
this from 1 to 15 seconds. 

The next position is the Day of the week—this MUST be SET for BK to refer the 
timer back to the Block of days you set above. 

And finally the time for the event, Must be set in Military time as necessary. (i.e. 
Lunch at 1:30 PM should be set in Military time as 13:30) 

Continue this process to set all of your time events. 

When finished press SET or leave the timer alone and it will return to the main screen. 

The screen reports the current status of the RELAY and generally it will always say Relay 
OFF until the vent time is reached and the Relay changes for that short period of time (1 
to 15 seconds depending on your event setting). 

Once programming is complete, your Electrical Professional can connect the horns, etc. 
using acceptable practices as per the NEC.

 

Содержание SSPT724A

Страница 1: ... can be left at DS if desired Press the Set button to reach the Press Enter to Set Evnt Event then press Enter Pressing Enter begins the curser scrolling the positions available for entry Event numbers begin at 01 and move up during subsequent event programming The entry position to the right of the MUST be set for PL pulse for all events you set The position further to the right is the duration t...

Страница 2: ... x 5 D Installation Instructions 1 Mount Unit in desired location Carefully Review Basic Operation pg 2 3 Terminal Identification Table pg 3 Push Button Layout and Description pg 3 Programming Instructions pgs 4 6 2 Connect 120 volts AC using AC power cord or hardwire as desired 3 Do Not Connect 12VDC battery optional for unique applications to terminals marked BAT 12VDC 4 Lithium battery is optio...

Страница 3: ... Legend Function Description NO C NC Dry Contact output used to switch controlled devices When these relays are energized ON the NC and C terminals are open and the NO and C terminals are closed When this relay is de energized Off the NC and C terminals are closed and the NO and C terminals are open DC AC or DC Input 12 to 24 volt When using DC carefully observe polarity This is already wired AC t...

Страница 4: ...ode OFF Relay OFF latching mode PL Relay Pulse momentary appears in display and depressing ENTER will make selection When selecting the pulse mode PL01 will appear in the display It is now necessary to assign the length of time duration of relay activation The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons then depressing ENTER...

Страница 5: ...epress ENTER to accept You may continue to program more holiday events by repeating the previous steps or exit programming by depressing SET E Setting Holiday Dates It is now necessary to assign these holiday events specific calendar dates which they are to occur To select Holiday events depress SET until ENTER to SET HOL Depress ENTER 01 HOL SU 00 00 Note Holiday events will override all regularl...

Страница 6: ...sing SET until ENTER to CLR MEM Depress ENTER CLEAR MEMORY Depress ENTER PRESS UP ACCEPT Depressing UP push button will now clear all events previously programmed If you wish to escape from this selection depress any of the other push buttons SET ENTER and DWN appears in display ...