Lawn Master
TM
II Landscape Timer
Models: 53805 (4-Zone) & 53806 (6-Zone)Installation & Programming Guide
English
Spanish
Downloaded from
www.Manualslib.com
manuals search engine
Страница 1: ...Lawn MasterTM II Landscape Timer Models 53805 4 Zone 53806 6 Zone Installation Programming Guide English Spanish Downloaded from www Manualslib com manuals search engine...
Страница 2: ...E DAY Setup Page 8 WATERING DAYS Setup Page 9 START TIMES Setup Page 10 SET ZONE TIMES Setup Page 11 SEASON ADJUST Setup Page 12 MANUAL STATION Operation Page 12 MANUAL PROGRAM Operation Page 13 Turni...
Страница 3: ...the previous menu item Navigate to the next menu item Adjust Increase the selected value Adjust Decrease the selected value 5 Terminal Block RS1 RS2 Sensor AC1 AC2 AC Power COM Valve Common MV Master...
Страница 4: ...ied station to run The run times can be set from one minute and up to six hours SEASON ADJUST Select to adjust the program s watering by percentage You can decrease your irrigation system s watering d...
Страница 5: ...n sensor optional is installed SENSOR indicates that rain has been detected 7 PROGRAM A B or C Indicates which program is selected 8 Season Adjust Indicates that the automatic programs have been adjus...
Страница 6: ...the two screws horizontally Install two screws 5 inches 12 7 cm apart into the wall at eye level Leave the screw extended approximately 1 4 inch 6 mm from the wall to accommodate the controller case I...
Страница 7: ...he current time date and scheduled programs are retained IMPORTANT Check the controller s scheduled watering program after every power outage to prevent interruption to your irrigation system s activi...
Страница 8: ...sensor switch must be in the OFF position or the jumper wire must be installed Step 1 Remove the controller s lower panel cover to access the sensor terminals Step 2 Route the rain sensor s cable to...
Страница 9: ...g solenoid lead from each valve For reference note the wire color code being used for each valve connection and the associated watering station Step 3 Remove the controller s lower panel cover to acce...
Страница 10: ...e current month s value Press button to advance to DAY Step 4 With DAY displayed press or to adjust the current day s value Press to advance to AM PM Step 5 With AM or PM flashing press or to select A...
Страница 11: ...on watering day To enable a non watering day press or until the desired weekday is flashing Press to enable The icon will be displayed above the active day Step 4 For ODD scheduling press or until ODD...
Страница 12: ...ified Step 4 Press or to adjust the time to the desired START TIME For unused start times make sure OFF is displayed OFF is located between 11 45pm and 12 00am Each key press will increase or decrease...
Страница 13: ...ep 3 Press or to select the Zone station number 1 6 being modified Step 4 Press or to adjust the desired time duration runtime you want the station to be active Each station can have a runtime of one...
Страница 14: ...MANUAL STATION Operation MANUAL STATION operation enables you to activate any station and give a temporary run time duration Only one station can be activated by the MANUAL STATION operation Any run...
Страница 15: ...To modify the station run times temporarily press or to select the Station number being modified Press or to adjust the desired run time duration Step 5 Turn the function dial slowly to the RUN positi...
Страница 16: ...T set to 0 AC power source is not connected NO AC is displayed Battery is weak or missing Mechanical override Valve s manual bleed is ON Function Dial was rotated too quickly to the RUN position Corre...
Страница 17: ...at 0 75A Capacity One Station plus Master Valve or 24 VAC Pump Start Relay Active at one time Maximum Electrical Output 350mA per Station Operating Temperature 32 F to 140 F 0 C to 60 C Storage Temper...
Страница 18: ...tion loss the cost of substitute equipment or services required during periods of malfunction or resulting non use property damage or personal injury resulting from installer s negligence Some states...
Страница 19: ...art time number being set 3 start times per program Press or to adjust the start time SET ZONE TIMES Place function dial to position Press or to select the station number Press or to adjust the statio...
Страница 20: ...18 2007 The Toro Company Consumer Division www toro com Made in China Part Number 373 0445 Rev B 5 Inches 12 7cm Downloaded from www Manualslib com manuals search engine...
Страница 21: ...Temporizador para zonas verdes Lawn MasterTM II Modelos 53805 4 zonas y 53806 6 zonas Gu a de instalaci n y programaci n English Spanish Downloaded from www Manualslib com manuals search engine...
Страница 22: ...ste de D AS DE RIEGO P gina 9 Ajuste de HORAS DE ARRANQUE P gina 10 Ajuste de TIEMPOS DE RIEGO POR ZONAS P gina 11 Ajuste de RIEGO PORCENTUAL P gina 12 Funci n ESTACI N MANUAL P gina 12 Funci n PROGRA...
Страница 23: ...anterior Ir al elemento de men siguiente Ajustar Aumentar el valor seleccionado Ajustar Reducir el valor seleccionado 5 Bloque terminal RS1 y RS2 Sensor AC1 y AC2 Potencia CA COM Cable com n de v lvul...
Страница 24: ...ajustarse entre un minuto y seis horas SEASON ADJUST Ajusta porcentualmente el riego de cada programa Puede reducirse el tiempo de riego del sistema al 0 Sistema OFF apagado o aumentar el tiempo de ri...
Страница 25: ...ctado lluvia 7 PROGRAM A B o C Indica el programa seleccionado 8 Season Adjust Indica que los programas autom ticos han sido ajustados 9 AM o PM Indica la hora en formato AM ma ana o PM tarde 10 Riego...
Страница 26: ...nte los dos tornillos Instale dos tornillos en la pared al nivel de los ojos con una separaci n entre s de cinco pulgadas 12 7 cm Los tornillos deben sobresalir aproximadamente 1 4 pulgada 6 mm de la...
Страница 27: ...hora y los programas IMPORTANTE Cada vez que se produzca un corte de energ a el ctrica compruebe el programa de riego del programador para evitar interrupciones en la actividad de su sistema de riego...
Страница 28: ...debe estar en la posici n OFF o debe instalarse el cable puente Paso 1 Retire la tapa del panel inferior del programador para tener acceso a los terminales del sensor Paso 2 Lleve el cable del sensor...
Страница 29: ...cada v lvula Para su referencia anote el color del cable usado para cada conexi n de v lvula y la estaci n de riego asociada Paso 3 Retire la tapa del panel inferior del programador para tener acceso...
Страница 30: ...se para avanzar a DAY Paso 4 Con DAY en pantalla pulse o para ajustar el valor al d a actual Pulse para avanzar a AM PM Paso 5 Con AM o PM parpadeando pulse o para seleccionar AM ma ana o PM tarde Pul...
Страница 31: ...riego pulse o hasta que parpadee el d a de la semana deseado Pulse para habilitar ese d a Se mostrar el icono en la pantalla encima del d a activo Paso 4 Para el calendario ODD d as impares pulse o ha...
Страница 32: ...ora de arranque deseada Para las horas de arranque sin utilizar aseg rese de que la pantalla muestre OFF deshabilitado OFF est situado entre las horas de 11 45pm y 12 00am Cada pulsaci n adelanta o re...
Страница 33: ...na estaci n 1 6 a modificar Paso 4 Pulse o para ajustar el tiempo de riego durante el cual la estaci n debe estar activada El tiempo de riego de cada estaci n puede ajustarse entre un minuto y seis ho...
Страница 34: ...ci n manual le permite activar manualmente cualquier estaci n y establecer un tiempo de riego temporal S lo es posible activar una estaci n utilizando la funci n MANUAL STATION Cualquier ajuste del ti...
Страница 35: ...temporalmente los tiempos de riego de las estaciones pulse o para seleccionar el n mero de la estaci n a modificar Pulse o para ajustar el tiempo de riego Paso 5 Gire el dial de funciones lentamente...
Страница 36: ...si agotada Sobrecontrol mec nico la purga manual de la v lvula est en ON El dial de funciones se gir demasiado r pidamente a la posici n RUN Soluci n Compruebe y cambie el solenoide Compruebe las cone...
Страница 37: ...a a 0 75 A Capacidad Una estaci n m s v lvula maestra o rel de arranque de bomba de 24 Vca activa en cualquier momento Temperatura de operaci n 32 F a 140 F 0 C a 60 C Temperatura de almacenamiento 4...
Страница 38: ...urante periodos de aver a o la p rdida consiguiente de uso da os materiales o lesiones personales que son el resultado de la negligencia del instalador Algunos estados no permiten exclusiones de da os...
Страница 39: ...que por programa a establecer Pulse o para ajustar la hora de arranque Establecer TIEMPOS DE RIEGO Ponga el dial de funciones en la posici n Pulse o para seleccionar el n mero de estaci n Pulse o para...
Страница 40: ...18 2007 The Toro Company Divisi n de Consumo www toro com Fabricado en China Pieza N 373 0445 Rev AB 5 pulgadas 12 7 cm Downloaded from www Manualslib com manuals search engine...