G. Delete All Events:

All previously programmed events can be deleted by depressing 

SET

until

ENTER to

CLR MEM

Depress 

ENTER

CLEAR

MEMORY?

Depress 

ENTER

PRESS UP

& ACCEPT

Depressing 

UP

push button will now clear all events previously programmed.

If you wish to escape from this selection depress any of the other push buttons: 

SET

,

ENTER

and

DWN

.

PT724AE
Enclosure Dimensions:

8.5”

H

 x 7.5”W x 3.5”D

2"

4"

3.63"

1.25"

0

7.25"

2.25"

0

0

3.5"

8"

1.13"

7"

.625"

6.75"

4"

7"

3.5"

3.63"

2.25"

3.5"

0

8"

LEFT

RIGHT

BACK

TOP ONLY

appears in display.

will appear in display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SSPT724A

Страница 1: ... can be left at DS if desired Press the Set button to reach the Press Enter to Set Evnt Event then press Enter Pressing Enter begins the curser scrolling the positions available for entry Event numbers begin at 01 and move up during subsequent event programming The entry position to the right of the MUST be set for PL pulse for all events you set The position further to the right is the duration t...

Страница 2: ... x 5 D Installation Instructions 1 Mount Unit in desired location Carefully Review Basic Operation pg 2 3 Terminal Identification Table pg 3 Push Button Layout and Description pg 3 Programming Instructions pgs 4 6 2 Connect 120 volts AC using AC power cord or hardwire as desired 3 Do Not Connect 12VDC battery optional for unique applications to terminals marked BAT 12VDC 4 Lithium battery is optio...

Страница 3: ... Legend Function Description NO C NC Dry Contact output used to switch controlled devices When these relays are energized ON the NC and C terminals are open and the NO and C terminals are closed When this relay is de energized Off the NC and C terminals are closed and the NO and C terminals are open DC AC or DC Input 12 to 24 volt When using DC carefully observe polarity This is already wired AC t...

Страница 4: ...ode OFF Relay OFF latching mode PL Relay Pulse momentary appears in display and depressing ENTER will make selection When selecting the pulse mode PL01 will appear in the display It is now necessary to assign the length of time duration of relay activation The pulse can range in length from 1 second minimum to 15 seconds maximum and is selected by using UP or DWN push buttons then depressing ENTER...

Страница 5: ...epress ENTER to accept You may continue to program more holiday events by repeating the previous steps or exit programming by depressing SET E Setting Holiday Dates It is now necessary to assign these holiday events specific calendar dates which they are to occur To select Holiday events depress SET until ENTER to SET HOL Depress ENTER 01 HOL SU 00 00 Note Holiday events will override all regularl...

Страница 6: ...sing SET until ENTER to CLR MEM Depress ENTER CLEAR MEMORY Depress ENTER PRESS UP ACCEPT Depressing UP push button will now clear all events previously programmed If you wish to escape from this selection depress any of the other push buttons SET ENTER and DWN appears in display ...

Отзывы: