ARC
CALIBRATION
ARC Calibration:
According to the local ground elevation, temperature, moderate and other environmental
factors to match the most suitable discharge ARC, in order to obtain the bestsplicing effect, we strongly
recommend you to do arc calibration when it is the first time to use the new machine, the seasonal changes, the
use place changes, or you replaced the electrodes;discharge correction should be done after changing the type
of fiber (such as single mode and multi-mode switching)
The procedure for ARC Calibration is as follows:
Step 1: Please turn on
the splicer machine, then
login Signalfire 2 on your
phone, connect the Bluetooth,
open the Arc Calibration
(See picture)
Step 2: After open the ARC Calibration, the icon
of Normal Mode "will change to the icon for"
ARC fiber,place the fiber to fiber holder and
close the o Calibration ". Then please strip
and cleave the windshield cover, the splicer
machine will perform the ARC calibration
automatically. (See picture)
Step 3: There is flash on the display screen
and slight burst from the ARC, the fiber head
is burning into a spherical shape the action
stops after the screen icon" "change
back to" "icon , it shows the ARC
calibration is successful. If the icon does not
change back to the Normal mode “ “ icon
the screen fiber still flashes,please
re-cleave the fiber and repeat the above
steps until the Arc calibration is successful.