SR 011
S-DIAS DC MOTOR MODULE
Page 30
20.03.2019
8
Wiring Examples
In the following sub chapters, wiring examples are provided. It must be ensured that all con-
structive measures etc. are complied with and applied in order to fulfil the requirements of the
category used.
8.1
Performance Level e, Category 4 or SIL 3
– Safety-SPS
To meet the requirements of category 4, performance Level "e" for EN ISO 13849-1 and SIL
3 according to EN 62061, two error-proof output of a Safety PLC must be used. Cross-circuit
detection between the two lines via the output tests of the STO 081 is hereby possible.