S-DIAS CPU MODULE
CP 313
29.05.2020
Page 11
4.2
Standard Configuration
Ethernet 1
X6
IP: 10.10.150.1
Subnet mask: 255.0.0.0
CAN bus
X2
Station 00
Baud rate: 01 = 500 kBaud
Problems can arise if a control is connected to an IP network, which
contains modules that are not running with a SIGMATEK operating system.
With such devices, Ethernet packets could be sent to the control with such
a high frequency (i.e. broadcasts), that the high interrupt load could cause a
real-time runtime error or runtime error. By configuring the packet filter
(Firewall or Router) accordingly however, it is possible to connect a network
with SIGMATEK hardware to a third party network without triggering the
error mentioned above.
Des problèmes peuvent survenir si un automate est connecté à un réseau
IP contenant des modules qui ne fonctionnent pas sous un système
d'exploitation SIGMATEK. Avec de tels dispositifs, les paquets Ethernet
peuvent
être envoyés à l’automate avec une fréquence tellement élevée
(càd. diffusion), que les interruptions ainsi générées peuvent provoquer une
erreur d'exécution. En configurant d’une façon appropriée le filtre de
paquets (pare-feu ou un routeur) il est toutefois possible de connecter un
réseau avec le matériel SIGMATEK à un réseau tiers sans déclencher
l'erreur mentionnée ci-dessus.
Содержание 20-004-313
Страница 15: ...S DIAS CPU MODULE CP 313 29 05 2020 Page 13...
Страница 17: ...S DIAS CPU MODULE CP 313 29 05 2020 Page 15 5 Mechanical Dimensions...
Страница 30: ...CP 313 S DIAS CPU MODULE Page 28 29 05 2020 9 Wiring 9 1 Wiring Example...
Страница 33: ...S DIAS CPU MODULE CP 313 29 05 2020 Page 31 10 Process Diagram...
Страница 56: ...CP 313 S DIAS CPU MODULE Page 54 29 05 2020...