12
When both setpoints are configured, scroll to ‘EXIT’ and press ‘ENTER’ to return to the ‘Main Menu’.
Select the ‘CLR’ to reset these values to the current process value and ‘EXIT’ and ‘ENTER’ to return to
the main screen.
MENU 1 ‘PASSWORD’
All access to the programmable functions are password protected. To change the unit’s access password,
Select the ‘PASSWORD’ block in menu 2, press ‘ENTER’ and using the Up/Down buttons, enter a new
numerical password.
Scroll to ‘EXIT’ to return to the main screen.
CAUTION: ENSURE THAT A RECORD IS KEPT OF THE PROGRAMMED PASSWORD.
ACCESS IS RESTRICTED TO ALL PROGRAMMABLE PARAMETERS WITHOUT THE
CORRECT PASSWORD.
MENU 1 ‘DEFAULT’
The ‘Default’ screen allows the operator to set a value that the analog output ‘defaults’ to at ‘Power Up’.
Use the
→
button from the Menu 1 screen to scroll to ‘DEFAULT’ and press ‘ENTER’. The cursor will
be highlighting the analog output value in percentage (%), that will output from the ROS at power up.
Use the
↑
↓
buttons to select the desired value and ‘NEXT’ to return to Menu 1.
Scroll to ‘EXIT’ and press ‘ENTER’ to return to the main screen.