Operation
Page
11
Output Channel Assignment
The sub-menu item is used to configure the routing matrix of defined inputs to spe-
cific physical output connectors. This is located under the main menu item.
V-FADES
The V-fade parameter enables the DA5315 to conceal AES framing errors that occur
upstream due to asynchronous switching or signal interruptions. With V-fade enabled, fast
error transitions (clicks and pops) are eliminated.
V-fades can be enabled through the menu item in Set-up.
OUTPUT SYNCHRONIZATION
The internal reference signal used for output synchronization is introduced into the frame
through a connector on the rear panel of the S5000 Signal Management System frame
labeled Video Reference. This reference is distributed throughout the frame by the CI5705
Communications Interface located above the power supplies. The reference signal can be
any valid NTSC or PAL video signal or AES Digital Audio. The DA5315 will match its ouptut
signal timing to be synchronized to this reference.
To have the DA5315 match its output signal timing to the internal reference the
menu setting must be set to ON. The Display Units setting (see Delay Display above) may
be changed to display delay in units that are consistent with the internal reference format.
OctaBus™ ID Assignment
To accurately identify the signals being put onto the OctaBus™ from multiple modules hav-
ing eight outputs, each module must have a unique module ID. This module ID is defined
via the menu selection which is available as a submenu from the main menu
item. The default ID for unconfigured modules is (1). If Octabus is not enabled or is not
being utilized, multiple modules in a system having identical Octabus ID’s is acceptable.
Anytime the channel designation requires an OctaBus™ ID, the display will show a decimal
between the last two characters - the next to last character being the OctaBus™ ID and the
last character being the channel number on the module specified by that OctaBus™ ID.
Reset Type/Initiation
Occasionally it may be necessary, or convenient, to clear the data stored in memory by
resetting the DA5315. Because it may be desirable to erase only some of the data, there