CC&CV Charge Mode
Battery Voltage @
Load >50%
Battery Voltage @50%>
Load > 20%
Battery Voltage @
Load < 20%
LCD Display
<48V
< 41.2V
< 43.6V
<44.8V
48-50V
41.2-43.2V
43.6-45.6V
44.8-46.8V
50-52V
43.2-45.2V
45.6-47.6V
46.8-48.8V
>52V
> 45.2V
> 47.6V
>48.8V
Load Information
Indicates overload.
Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%.
0%~24%
25%~49%
50%~74%
75%~100%
Mode Operation Information
Indicates AC input is available.
Indicates PV Input is available.
Indicates load is supplied by AC power.
Indicates the AC to DC charging.
Indicates the DC to AC conversion.
These three signs indicate the AC output priority. SOL.FIRST indicates solar
Priority. BAT.FIRST indicates battery priority. UTI.FIRST indicates utility
priority.
Mute Operation
Indicates unit audible alarm is disabled.
LCD SETTING
The M series inverter LCD allows users to virtually change all of its specs. It will enter setting mode if the
ENTER button is held for over 3 seconds. Press “UP” or “DOWN” button to select setting programs, and
then press the “ENTER” button to confirm the selection or the ESC button to exit.
Program 01: Power Priority for AC Loads
01 UEI: Utility Priority (Default)
In this mode, the utility will provide power to the AC loads as the first power source.
Solar and battery energy will provide power to the loads only when utility power is not available.