Measuring range for NH3
0..100 ppm
Max detecting concentration
200 ppm
Repeatability / Resolution / Stability per month
< 10% of Reading value / 1 ppm / < 2% of Reading value
Zero stability
+/- 2 ppm
Working atmospheric pressure
101.3 Kpa +/- 10%
Sensor life
> 2 years
Humidity and Temperature sensor
Digital type, factory calibrated
Humidity measuring range / accuracy / resolution
0 .. 100 %RH, ± 2.0% / 0.1%
Temperature measuring range / accuracy / resolution
-40 .. + 85°C / ± 0.2°C / 0.1°C
Working temperature and humidity
-30 .. + 50°C, 15 .. 90% RH
Sensor housing / Rating
SS316/SS304 housing with 316SS sintered filter / for Indoor use
Sigfox SPECIFICATION:
Sigfox zones
select RC1-RC2-RC4
Antenna
Internal Antenna 2dbi
Battery
02 x AA Type 1.5VDC, working time up to 10 years (depends on
configuration)
RF Module complies to
CE, FCC, ARIB
Working temperature
-40°C..+60°C (using Energizer Lithium Ultimate AA battery)
Housing/Protection
Al Polycarbonate / IP67
Dimension / Net weight
H180xW73xD42 / < 400 grams
4. Dimensions
5. Operation Principle
Содержание WSSFCB-NH3
Страница 9: ...Flow when coming from downlink ...
Страница 15: ...BLE broadcast ...
Страница 17: ...Signal received OK Signal received ALERT 1 ...
Страница 30: ...Steps for battery installation Step 1 Using M4 Hex key to open the cover 8 3 Battery installation ...