background image

COVER-5CKYER-0411(0)-SIESTA.indd2   2

COVER-5CKYER-0411(0)-SIESTA.indd2   2

6/10/11   11:04:49 AM

6/10/11   11:04:49 AM

Содержание ACQ 100 AV1

Страница 1: ...INSTALLATION MANUAL IM 5CKYER 0411 0 SIESTA Part No R08019036183 Models ACQ 71 AV1 ACQ 100 AV1 ACQ 125 AV1 Installation Manual Split Type Unit English ...

Страница 2: ......

Страница 3: ...B C D E F H K J I G Original Instruction All dimensions are in mm OUTLINE AND DIMENSIONS Dimension Model A B C D E F G H I J K ACQ 71 AV1 820 820 340 300 40 990 990 627 627 607 430 ACQ 100 AV1 ACQ 125 AV1 820 820 375 335 40 990 990 627 627 607 430 ...

Страница 4: ...as a result of the excessive heat Do not install the units at or near doorway Do not operate any heating apparatus too close to the air conditionerunitoruseinroomwheremineraloil oilvapour or oil steam exist this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction Whentheunitisusedinkitchen keepflourawayfromgoing into suction of the unit This unit is not suit...

Страница 5: ...ATION DIAGRAM Drain Piping Thermal Insulation Wrap the insulated pipe with the finishing tape from bottom to top Air Intake Grille Front Panel Air Filter behind the grille Air Discharge Louver To Outdoor Unit Indoor Unit ...

Страница 6: ...luctuation must not exceed 10 of rated voltage Electricity supply lines must be independent of welding transformers which can cause high supply fluctuation Ensure that the location is convenient for wiring piping and drainage Do not exert pressure on the resin parts when opening the unit or when moving it after opening Do not move the unit from packaging while moving until it reaches the installat...

Страница 7: ...water drainage Install the unit horizontally to prevent water leakage or condensation around the air outlet Indoor Unit Pipe Clamp Feed Water Flexible Drain Hose Main Drain Pipe Drain pipe must be in downward gradient for smooth drainage Avoid installing the drain pipe in up and down slope to prevent reversed water flow During the drain pipe connection be careful not to exert extra force on the dr...

Страница 8: ...If the unit need to be service steps below shall be followed 1 Confirm that the unit had been switched off before servicing the unit 2 Use screwdriver to unlock the screw on the cover lock grille 3 Remove the cover lock grille and open the intake grille for the service purpose 4 Install the intake grille and screw the cover lock grille after service and make sure the unit is proper install ...

Страница 9: ...re cover by removing 2 screws as shown in Figure 3 2 Wires will go through the hole as shown in Figure 4 and 5 respectively without crossing the height of the hole 3 After that wire cover will be assembled back to close the wire Figure 1 CAUTION Do not install the unit at altitude over 2000m for both indoor and outdoor Power supply terminal block Shape wires so that the stop valve cover fit secure...

Страница 10: ...on and burr remover at lower position to prevent metal chips from entering the pipe Insert the flare nuts mounted on the connection parts of both the indoor unit and outdoor unit into the copper pipes The exact length of pipe protruding from the top surface of the swaging block is determined by the flaring tool Refer Figure C Fix the pipe firmly on the swaging block Match the centers of both the f...

Страница 11: ...ng to moist air Residual POE or PVE oil in the piping and components can absorb moisture from the air To prevent mischarging the diameter of the service port on the flare valve is different from that of R22 Use tools and materials exclusively for refrigerant R410A Tools exclusively for R410Aare manifold valve charging hose pressure gauge gas leak detector flare tools torque wrench vacuum pump and ...

Страница 12: ...nection of the short duct for air discharge is possible on only one side The use of short duct for air discharge will improve airflow distribution if there is an obstruction such as a lighting fixture or in a long narrow room or an L shaped room It also use for air conditioning of two rooms simultaneously Possible Opening Dimension For Duct Connection Air Discharge Knock Out Hole Air Intake Knock ...

Страница 13: ...MEMO LE MÉMO MITTEILUNG MEMO EL MEMORÁNDUM ПАМЯТКА NOT ΣΗΜΕΙΩΜΑ MEMO ...

Страница 14: ... ËÌ ˆÛË fi ˆ Î ıÔÚ ÂÙ È ÛÙÔ A Î È ÎÚ ÓÂÙ È ıÂÙÈÎ fi ÙÔ B Û ÌÊˆÓ Ì ÙÔ ÈÛÙÔ ÔÈËÙÈÎfi C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A och godkänts av B enli...

Страница 15: ......

Страница 16: ...r cualquiera de las especificaciones y diseños contenidos en el presente manual en cualquier momento y sin notificación previa В случае противоречия перевода данного руководства с другими переводами одного и того же текста английский вариант рассматривается как приоритетный Завод изготовитель оставляет за собой право изменять характеристики и конструкцию в любое время без предварительного уведомле...

Отзывы: