Step 2. Pipe Wall Thickness
Press
or
then
to enter the pipe wall
thickness (wall thickness for various pipe schedules can be found in the
210i Instruction Manual, Appendix 1).
Step 3. Pipe Material
Press
or
then
. Use the
or
keys to select pipe material from the drop-down menu, and then
press the
key.
Step 4. Fluid Type
Press
or
then
. Use the
or
keys to select fluid type from the drop-down menu, and then
press the
key.
Step 5. Transducer Mounting Methods
Press
or
then
. Use the
or
keys to select transducer-mounting method from the drop-
down menu, and then press the
key. See
210 Instruction
Manual, Chapter 4
of instruction manual for details.
Step 6. Transducer Spacing
Press the
keys to enter Menu 25. Accurately install the transducer according to the displayed
transducer mounting spacing and the selected mounting method. Note: The spacing should be face to face. (See
210
Instruction Manual, Chapter 4
for details.)