RavenXTV CDMA Sierra Wireless Cellular Modem
1. Modem name: A unique name for the modem (the 10-digit MDN number
is recommended).
2. Domain: The domain name to be used by the modem (eairlink.com).
3. IP Manager IP Address: The IP or domain name of the dynamic DNS
server which is running IP Manager.
IPMANAGER1: edns2.eairlink.com
IPMANAGER2: eairlink.com
4. IP Manager update interval: How often you want the address sent to IP
Manager. If this is set to zero, the modem will only send an update if the
IP changes (i.e. if the modem is reset or is assigned a different IP). The
value can be set from 0 - 255 minutes.
Restrictions for Modem Name
•
Must begin with a letter or number
•
Can include a hyphen (-)
•
Cannot contain spaces
•
Must be no longer than 20 characters total
Click the
Write
icon to save the changes
.
Click the
Reset
icon to restart the modem.
Click the
Disconnect
icon to terminate communications with the modem.
6. LoggerNet/PC400 Software Setup
The Device Map is configured from the “Setup” button on the
LoggerNet/PC400 Toolbar. Configure the Device Map as described below.
1. Select Add Root | IPPort.
2. Add a datalogger to the IPPort (PakBus dataloggers, e.g. the CR1000,
require a PakBusPort).
3. On the IPPort page, add the IP address/domain name and the Port number
(the Raven template file configures the port to be 3001). Add four
seconds of extra response time.
4. For PakBus dataloggers, leave the default settings on the PakBusPort
page.
5. For PakBus dataloggers, set the PakBus address to match that of the
datalogger (default address in the datalogger is 1). Make sure that
“PakBus Always Open” is unchecked.
15