Operating Voltage
By default, the router is configured to enter Standby mode at 9 V. If you want to operate
the router at less than 9 volts, power it on using at least 9 V, launch ACEmanager, go to
Services > Power Management and adjust the Standby mode settings.
The maximum ripple voltage to guarantee analog input accuracy must be 100 mVpp.
Power Specifications
GNSS Technology
Table C-1: Power Supply Specifications
Pin
Name
Specification
Parameter
Minimum
Maximum
1
VCC
Voltage range
VCC
7 V
36 V
Table C-2: Ignition Sense Specifications
Pin
Name
Input Impedance
(Typ)
Specification
Parameter Minimum
Maximum
3
IS
(Input only)
80 kΩ (minimum)
Input low state voltage
(maximum)
V
IL
—
1.0 V
Input high state voltage
(minimum guaranteed)
V
IH
3.3 V
V
in
Note: If you do not connect this pin to the ignition, you MUST connect it to the positive terminal of your power supply or
battery. The device looks for a qualified voltage on this pin as part of the power up sequence. If it doesn’t see it, the
device will not turn on. If you are using a Sierra Wireless AC power adapter, the connection is inside the cable.
Satellite channels
Maximum 48 tracking channels and 2 fast acquisition channels
Constellations
•
GPS
•
Galileo
•
GLONASS
•
BeiDou
•
QZSS
Protocol
NMEA 0183 V3.0
Acquisition time (Time
to first fix)
•
Hot start: 1 second
•
Cold start: 30 seconds
Sensitivity
Indoor sensitivity (tracking mode): -162 dBm