Reliability Specifications
The RV55 router has an MTBF (Ground Benign, 25°C) as follows:
•
RV55 North America: 878875 hours (100.2 years)
•
RV55 International: 933291 hours (106.4 years)
•
RV55 North America and EMEA: 1413853 hours (161.4 years)
•
RV55 Asia Pacific: 1605817 hours (183.3 years)
MTBF calculations are performed per:
•
Telcordia “Reliability Prediction Procedure for Electronic Equipment” document
number SR-332, Method I, Issue 3
MIL-STD-810G,
Test method 507.5
Humidity
10 × 48-hour cycles:
•
4-hour ramp to 60 °C (95% humidity), hold 8 hours
•
4-hour ramp down to 30 °C (85% to 95% relative
humidity), hold 21 hours
•
1-hour ramp down to 20 °C, hold 4 hours
•
1-hour ramp up to 30 °C, hold 5 hours
Operating mode: powered on
IEC 60529
Water Resistance
Subject to spraying water. Water sprayed at an angle up
to 60° on either side of the vertical for 10 minutes.
Operating mode: unpowered
IEC 61000-4-2
Electrostatic
Discharge
+/-8 kV (Contact), +/-15 kV (Air)
+/-15 kV (Air at antenna connector)
Operating mode: powered on
IEC 60068-2-32
Free Fall Test
1 m drop height
6 drops onto concrete, 2 per axis: X, Y, Z
Operating mode: unpowered
IEC 60068-2-70
Part 2, Test Xb
Marking
The markings are rubbed with water for 10 cycles, then
with lubricating oil for 10 cycles.
Operating mode: unpowered
ISTA 2A 2001,
test categories 1,
4, 5, & 6
Package
In shipping packaging.
Cargo vibration and drop test.
IP rating
IP64
Test Method
Category
Description