4116298
Rev 7.0
November 07, 2016
12
Product Technical Specification and
User Guide
Overview
1.1.5.2.
Disposing of the Product
This electronic product is subject to the EU Directive 2012/19/EU for Waste Electrical
and Electronic Equipment (WEEE). As such, this product must not be disposed of at a
municipal waste collection point. Please refer to local regulations for directions on
how to dispose of this product in an environmental friendly manner.
1.2.
Functional Architecture
The global architecture is shown in the figure below.
Figure 2.
Functional Architecture
1.2.1.
RF Functionalities
The Radio Frequency (RF) range complies with the 3GPP requirements. The corresponding
frequency recommendations for both transmission and reception bands are listed in the table below.
Table 2.
Supported Bands/Connectivity
RF Band
Transmit band (Tx)
Receive band (Rx)
Maximum Output Power
UMTS B1
1922 to1978 MHz
2112 to 2168 MHz
23 dBm (+/- 2dBm) Class 3bis
UMTS B2
1852 to 1908 MHz
1932 to 1988 MHz
23 dBm (+/- 2dBm) Class 3bis
UMTS B5
826 to 847 MHz
871 to 892 MHz
23 dBm (+/- 2dBm) Class 3bis
UMTS B6
832 to 838 MHz
877 to 883 MHz
23 dBm (+/- 2dBm) Class 3bis
UMTS B8
882 to 913 MHz
927 to 958 MHz
23 dBm (+/- 2dBm) Class 3bis