7.2.6.
Handling Resistance Stress Tests
The following tests the modem
’s resistance to handling malfunctions and damage.
Table 29.
Handling Resistance Stress Tests
Designation
Condition
ESD Test
Standard: IEC 61000-4-2
Special conditions:
Contact discharges: 10 positive and 10 negative applied (Voltage:
±2kV, ±4kV, ±6kV)
Air discharges: 10 positive and 10 negative applied (Voltage: ±2kV,
±4kV, ±8kV)
Operating conditions: Powered
Duration: 72 hours
Free Fall Test
FFT
Standard : IEC 60068-2-32, Test Ed
Special conditions:
Drop: 2 samples for each direction
Equivalent drop height: 1m
Number of directions: 6 (±X, ±Y, ±Z)
Number of drops/face: 2
Operating conditions: Un-powered
Duration: 24 hours