background image

6

CHARGING

For maximum efficiency and battery life, charge before first use and after each use. Charge the 
batteries every 3-6 months if it is being stored for a long period of time. Failure to properly charge as 
listed below could damage the unit and affect performance.

Two methods of charging are available:
• 

Use the included 120V/220V – 15V 10A AC Charger

• 

Use a compatible solar panel (Sierra Wave #9580 & #9590 Solar Collectors recommended)

Main Power Key: Turning clockwise (ON) allows all charging and operation features.  Turning 
counterclockwise (OFF) disengages all operations. It should be in the OFF position during charging. 
The key should be removed when not in use.

AC Charging: (included)

1. 

The MAINPOWER KEY should be in the OFF position and the INVERTER ON/OFF switch and the 
DC ON/OFF switch should be OFF.

2. 

Plug the AC Charger into the DC IN socket. Make sure that the charger input voltage selector is 
set for your area – this is either 120V or 220V.

3. 

Find a suitable 120V AC outlet and plug in the power cord.

4. 

CHARGING INDICATORS:
• 

The RED LED on the charger will glow when charging is in progress.

• 

The GREEN LED on the charger will glow and the RED LED will turn off when the battery is 
completely charged.

5. 

The BATTERY METER will indicate the strength of the battery – All 10 LEDs means the unit is 
fully charged. Recharge as needed.

6. 

Disconnect the charger once charging is complete.

Solar Charging: (solar panel not included)

The Energy Center has a built in Linear Solar Charge Controller that can accept 12V and 24V solar 
panel systems, up to a maximum input of 150 watts. Aervoe recommends the Sierra Wave #9580 80-
Watt Solar Collector or the Sierra Wave #9590 120-Watt Solar Collector.

An ANDERSON TO MC4 ADAPTER CABLE is provided to connect Sierra Wave solar panels, or other 
compatible collectors, directly into the Energy Center. #9503 30 ft. Extension Cable is available if a 
longer cord is needed in order to keep the #9675 indoors while charging.

1. 

Follow instructions provided with the solar panel. 

2. 

Connect the MC4 cables on the solar panel to the included MC4 ADAPTER CABLE and the plug 
the ANDERSON plug into the SOLAR IN socket. If using a solar panel or adapter cable other than 
Sierra Wave, observe the /- polarities and wattage recommendations. IMPORTANT: do 
not connect to the DC IN port as a malfunction can occur.

3. 

When solar voltage is present, the SOLAR INPUT LED will glow RED.

4. 

When charging is complete the SOLAR CHARGE COMPLETE LED will glow GREEN.

5. 

The BATTERY METER will indicate the status of charging – All 10 LEDs means the unit is fully 
charged. Recharge as needed.

6. 

Disconnect the solar collector once charging is complete.

Содержание Solar Link 1000

Страница 1: ...OPERATING INSTRUCTIONS 1000 Watt Energy Center PatentPending...

Страница 2: ...operate in flammable or explosive environments Do not operate if the unit is damaged in any way including loose electronics or if charging cords are frayed and wires are exposed Do not plug inverter 1...

Страница 3: ...e reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with...

Страница 4: ...4 120V AC CHARGER PARTS IDENTIFICATION Inverter Exhaust Fan Solar Input LED Solar IN Solar Charge Complete LED DC IN POWER IN ANDERSON TO MC4 ADAPTER CABLE...

Страница 5: ...5 Earth Ground 220V AC Outlet Inverter ON OFF Status LEDs Volt AMP Meter 12V DC Outlets 12V DC Fuses USB Ports Battery Meter DC ON OFF Battery Meter ON OFF POWER OUT Main Power Keyhole MAIN POWER KEY...

Страница 6: ...ER will indicate the strength of the battery All 10 LEDs means the unit is fully charged Recharge as needed 6 Disconnect the charger once charging is complete Solar Charging solar panel not included T...

Страница 7: ...ces rated at up to 1000W Peak 1 Turn off the INVERTER ON OFF switch and remove MAIN POWER KEY before plugging in any appliance into the 120V outlet 2 Turn on the MAIN POWER KEY and switch the INVERTER...

Страница 8: ...tage during use 4 Disconnect and turn the power off when not in use 12 VOLT DC OPERATION 15A 150 watt each outlet max 1 Turn the MAIN POWER KEY and DC power switch to the ON position 2 Plug in your 12...

Страница 9: ...ficient battery charge available If not follow the charging steps previously described on page 6 Ensure the DC ON OFF switch is ON and the green light is ON Check to make sure that the 12V DC circuit...

Страница 10: ...ERTER SAFETY FEATURES Electronic overload protection with automatic shutdown Built in internal backup DC fused provides added safety Low battery voltage warning followed by automatic shutdown Over tem...

Страница 11: ...mes To estimate how many hours of power are in the Solar Link find the watt hour draw of the device that you wish to power and divide into 740W 120V AC or 820W USB 12V DC EX One 12V 10 watt light 82 h...

Страница 12: ...12 AERVOE INDUSTRIES INC Gardnerville NV 89410 1 800 227 0196 www aervoe com mailbox aervoe com 9675inst cs1 16...

Отзывы: