ELECTRICAL TROUBLE SHOOTING

W ARNING:

 

Only a trained technician should attem pt to

repair  a  pellet  heater  electrical  system .

Note: All tests should be accomplished with the unit
therm ostat by-passed. 

Rem ove both AC and DC power from  unit. The igniter
system  is protected with a 5 am p fuse located on the back
or side of the heater 

(Figure 1)

. The igniter is switched “Off”

and “On” by the control system  via a relay located in the
lower right pedestal in front of the control board
(EF3801/5001) or in lower left rear of the unit accessed
from  the back (EF4001). W iring on all igniter system s are
the sam e. The following test steps will require a m ulti-m eter
with AC/DC volt and ohm  functions:  

a.

Unplug heater from  wall outlet and 12VDC power!

b.

Rem ove 5 am p fuse holder cap and fuse by pressing
in and turning counter clockwise. Test fuse with ohm
m eter to confirm  is not “open”. If fuse is open go to
Testing Igniter “d”. If fuse is good continue.

c.

Check 115VAC power wire connection to relay and
neutral wire connection to igniter term inal. This can
be accom plished with the ohm  m eter. If wire is
disconnected or open replace.

 

d.

Disconnect igniter leads from  relay and neutral. Test
continuity with ohm  m eter between leads. If open
igniter is defective. If continuity exists then check for
internal grounding by checking each lead to the
shielded conduit of the igniter leads. If continuity
exists to ground then igniter is defective. If m eter
reads open on both leads to ground then igniter
should produce heat when properly connected to
115VAC.

 

e.

W ith igniter disconnected from  relay, attach volt
m eter (set m eter to 200VAC)  leads to relay 115VAC
out term inal and igniter neutral. Reapply 115VAC
power. Press operating button low. Relay should
im m ediately engage applying 115VAC to m eter. If
m eter has 115VAC then replace igniter as it should
be activated. If no AC power outputted from  relay.
Continue to next test.

 

f.

Disconnect DC control wires from  harness to relay.
Attach volt m eter (set m eter to 20VDC)  leads to
harness term inals. Reapply 115VAC power. Press
operating button low. Control system  should
im m ediately engage applying 12VDC to m eter. If
m eter has 12VDC then replace relay as it should be
activated. If relay does not engage, exchange control
board and/or m ain switch board.

REPLACEMENT PARTS:

ITEM

NO.

PART

NO.

DESCRIPTION

1

120120

12VDC RELAY

2

120117

CARTRIDGE HEATER

3

120118

AUTOLITE CONTROL SW ITCH

4a

202163

BURN POT SCREEN 5001

4b

202164

BURN POT SCREEN 3801/4001

5a

300501

BURN POT 5001-AUTOLITE

5b

300500

BURN POT 3801/4001-AUTOLITE

6

110510

5 AMP FUSE MDL5 (NOT SHOW N)

Custom er Service & Replacem ent Parts

Replacement parts are available from your local dealer or
on-line @  www.sierraproductsinc.net . or call or write:

Customer Service
Sierra Products, Inc.
5061 Brooks St. Ste. B,
Montclair, CA 91763
Phone 1-909-399-3355 
Fax 1-909-399-3357
www.sierraproductsinc.net

Содержание EasyFire EF 3801

Страница 1: ...40154 R1 1 05 rb MODEL EF 5000 PELLET HEATER MODEL EFI 4000 PELLET INSERT MODEL EF 3800 PELLET HEATER MODEL EF3801PELLET HEATER Pellet Heater Repair Manual Please familiarize yourself with entire manu...

Страница 2: ...ice Philosophy p 3 2 Tools Service Kit p 4 3 Warranty Return Parts Policy p 5 4 Sample Claim Form p 6 5 Service Calls p 7 6 Trouble Shooting Flow Charts p 8 7 Electric Schematic p 19 20 8 Component Re...

Страница 3: ...entering the customer s home the service person should be neat and clean in appearance have the necessary tools and parts required to attend to the problem and share with the customer an explanation o...

Страница 4: ...oated slot screw drivers d Flashlight e Extension cord with ground f Allen wrench set long handle g W ire stripper and cutter h Electrical continuity tester with light or LED i Fully charged 12V Gel C...

Страница 5: ...sequential damages so the above limitations or exclusions may not apply to you SPI s warranty obligation and the purchaser s rights under it can be altered only by a subsequent written agreement betwe...

Страница 6: ..._________________ _____________________________________________________ _____________________________________________________ Describe Repair _____________________________________________________ ____...

Страница 7: ...f failure on a statistical basis In practice however it should be the most reliable due to the rigorous test procedure each board goes through before being installed on the stoves Because of this mech...

Страница 8: ...8 Trouble Shooting Flow Chart 1 Stove not running at all...

Страница 9: ...9 Trouble Shooting Flow Chart 2 Feed motor runs but no fan Trouble Shooting Flow Chart 3 Fan motor runs but no feed...

Страница 10: ...low Chart 4 Stove runs but shuts down in 10 minutes Make sure stove is hot enough 140 F Trouble Shooting Flow Chart 5 Stove runs but shuts down randomly with over temp LED On Steady Red High Temp Blin...

Страница 11: ...11 Trouble Shooting Flow Chart 6 Stove runs heat output stays Low even on High setting Trouble Shooting Flow Chart 7 Stove will not run on battery or charge battery...

Страница 12: ...Stove runs in fan only mode but when turned to Low Med or High it shuts off immediately Trouble Shooting Flow Chart 9 Fan always very high all modes except off Trouble Shooting Flow Chart 10 Feed alwa...

Страница 13: ...wn and when it reaches a lower temperature will shut down automatically This can be corrected by adjusting the feed setting to a higher setting Trouble Shooting Flow Chart 11 Stove runs fine and then...

Страница 14: ...14 2005 and newer control switch assembly Pre 2005 control switch assembly...

Страница 15: ...fuel shot Smoke will be visible normally visible through the door glass with in 2 minutes C Feed will cycle ON for short periods during the start cycle add small amounts of fuel Heater continue in STA...

Страница 16: ...than three times so the circuit does not become damaged by overheating 3 Pellets Jammed in feed shoot above burn pot Remove all jammed pellets and clean shoot with scraper Ignitor does not heat up The...

Страница 17: ...hange system and can be correct by cleaning Over Feeding Over feeding is a common problem and is related to a lack of combustion air rather than to much fuel If the heater is clean and seems to feed m...

Страница 18: ...sensor allows for cabinet air to drawn through the high temp plastic holder W hen door is open or flue blocks the flow reverses T 2 sensor is attach to a aluminum block and attached to the manifold W...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...ong with feed motor for 1 minutes providing start up fuel 3 Pellets start to ignite approx 3 to 4 minutes Feed motor starts at 4 minutes to provide additional start up fuel 4 At 7 minutes unit should...

Страница 22: ...ng by checking each lead to the shielded conduit of the igniter leads If continuity exists to ground then igniter is defective If meter reads open on both leads to ground then igniter should produce h...

Страница 23: ...Sierra Products Inc 5061 Brooks St Ste B Montclair CA 91763 P N 140804 10 07 23...

Страница 24: ...Sierra Products Inc 5061 Brooks St Ste B Montclair CA 91763 P N 140804 10 07 24 Pre 2004 Pellet Stove Wiring Detail...

Страница 25: ...Sierra Products Inc 5061 Brooks St Ste B Montclair CA 91763 P N 140804 10 07 25 2005 HARNESS WIRING DETAIL...

Страница 26: ...ess connections note location of red banded wire on motor to assure proper rotation of motor Remove wing nuts or 10 nuts on some units attaching feed motor bracket to rear of feed shoot Gently remove...

Страница 27: ...ng replacement of the sensors and offering a repair credit Please contact customer service 800 527 4790x29 for further information T 1 and T 2 Sensor Replacement Removal from 3801 and 4001 Insert The...

Страница 28: ...fan motor base plate to the housing Carefully pry the base plate breaking the factory silicon seal Remove motor from unit Using a long allen wrench loosen the allen set screws holding the combustion f...

Страница 29: ...5061 Brooks St Montclair CA 91763 909 399 3355 Fax 1 909 399 3357 www sierraproductsinc com 29...

Страница 30: ...5061 Brooks St Montclair CA 91763 909 399 3355 Fax 1 909 399 3357 www sierraproductsinc com 30...

Отзывы: