Siemens XJ-L Busway System Скачать руководство пользователя страница 2

1.0 Definitions

1.1 QUALIFIED PERSONNEL

FOR THE PURPOSE OF THIS MANUAL AND
PRODUCT LABELS, QUALIFIED PERSONNEL
IS ONE WHO IS FAMILIAR WITH THE
INSTALLATION, CONSTRUCTION AND
OPERATION OF THE EQUIPMENT AND THE
HAZARDS INVOLVED.  IN ADDITION, HE OR
SHE HAS THE FOLLOWING QUALIFICA-
TIONS:

(a)

Is trained and authorized to energize, de-energize,  

clear, ground and tag circuits and equipment in 
accordance with established safety practices.

(b)  

Is trained in the proper care and use of protective 

equipment such as rubber gloves, hard hat, safety 
glasses or face shields, flash clothing, etc., in 
accordance with established safety practices.

(c)

Is trained in rendering first aid.

1.2 DANGER

FOR THE PURPOSE OF THIS MANUAL AND PRODUCT
LABELS, DANGER INDICATES AN IMMINENTLY HAZ-
ARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL
RESULT IN DEATH OR SERIOUS INJURY.

1.3 WARNING

FOR THE PURPOSE OF THIS MANUAL AND PRODUCT
LABELS, WARNING INDICATES A POTENTIALLY 
HAZARDOUS SITUATION WHICH, IF NOT AVOIDED,
COULD RESULT IN DEATH OR SERIOUS INJURY.

1.4 CAUTION

FOR THE PURPOSE OF THIS MANUAL AND PRODUCT
LABELS, CAUTION INDICATES A POTENTIALLY 
HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, MAY
RESULT IN MINOR OR MODERATE INJURY.

2.0 Storage Instructions

Upon receipt, immediately inspect busway components
for possible concealed damage from shipping and/or
handling.  If damage has occurred, file a claim with the
carrier.  If there is no damage, restore the packing to its
original condition to prepare for job site storage.

Store busway indoors in a clean and dry area. Protect
against mechanical damage and exposure to lime dust
(concrete), water, corrosive fumes or liquids and salts.
Failure to properly store and protect the busway can
cause damage and will void the warranty.

3.0 Preparing for Installation

Deliver busway to installation location before unpacking.
Shipping crates/cartons contain exterior identification of
the packaged busway components. Each busway com-
ponent is further identified by an item number located
on the nameplate, which corresponds to that same item 
number on the busway installation drawing(s). 

Inspect each busway component for possible damage.
Consult the factory.  Confirm that contact surfaces are
not damaged and are clean and dry.  Abrasives should
not be used on these surfaces because contact surfaces
are electroplated. Inspect joint insulators for cracking or
any sign of damage.

Megger each busway component at 1000 volts, phase
to phase and phase to ground, to verify insulation
integrity.  Minimum readings should be no less than:

Megohms = 200 / length of run in feet

Or

= 66 / length of run in meters

If readings are below this minimum, do not apply power
to the installed busway and contact Siemens.

2

Содержание XJ-L Busway System

Страница 1: ...XJ L Busway Systems Storage Installation and Maintenance Instructions for Piece No 32 J 1010 01 Rev 5 SIEMENS XJ L Busway System ...

Страница 2: ...ect busway components for possible concealed damage from shipping and or handling If damage has occurred file a claim with the carrier If there is no damage restore the packing to its original condition to prepare for job site storage Store busway indoors in a clean and dry area Protect against mechanical damage and exposure to lime dust concrete water corrosive fumes or liquids and salts Failure ...

Страница 3: ...pply pressure to either side of the assembly left hand and then right hand until fully seated 4 0 1 7 Close joint inspection cover and secure it with provided hardware The joint is now complete 4 1 Hanger Instructions XH2 XH3 4 1 1 TO HANG XJ L BUSWAY FROM DROP RODS 4 1 1 1 Position drop rods as required Max 10 Spacing 4 1 1 2 Using a double nut configuration assemble the hanger halves to each dro...

Страница 4: ... 1 1 XJ L Bus plugs are available with molded case circuit breakers or Vacu Break fusible switches Bus plugs may be operated with a pull chain or hookstick from the floor Lightweight and portable plugs are easily moved from one location to another Captive hardware allows for easy removal and re installation 5 1 2 The bus plug contact fingers are lubricated with an oxide inhibiting grease at the fa...

Страница 5: ... busway 5 2 5 Guide the bus plug into the outlet opening ensuring that the bus plug alignment finger and bus plug conductor fingers enter their corresponding openings in the outlet 5 2 6 Push the bus plug firmly into the busway plug in outlet 5 2 7 Make sure the bus plug is fully seated on the busway housing and then tighten all mounting screws 5 2 8 6 and 12 circuit XPMs are provided with drop ro...

Страница 6: ...SE PROCEDURES DO NOT REPRESENT AN EXHAUSTIVE SURVEY OF MAINTENANCE STEPS NECESSARY TO ENSURE SAFE OPERATION OF THE EQUIPMENT PARTICULAR APPLICATIONS MAY REQUIRE ADDITIONAL PROCEDURES SHOULD ADDI TIONAL INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER S PURPOSES THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE OR CALL 1 8...

Отзывы: