background image

1

Safety instructions     

– The washing machine is heavy - take care when lifting it.
– Warning: frozen hoses may tear/burst. Do not install the washing machine outdoors or in 

areas where there is a risk of frost.

– The washing machine may be damaged. Do not lift by projecting components (e.g. washing 

machine door).

– In addition to the instructions mentioned here, special regulations of the relevant water and 

power supply companies may apply.

– If in doubt, have the appliance connected by a technician.
– Lay hoses and cables in such a way that there is no risk that they can be tripped over.

Environmental disposal

– Dispose of packaging in an environmentally friendly manner.
– This appliance has been identified in accordance with the European Directive 2002/96/

EEC on Waste Electrical and Electronic Equipment (WEEE). The Directive specifies a 
framework for the return and recycling of waste appliances and is valid throughout Europe.

Scope of delivery 

according to model

Humidity in the drum is

caused by the final inspection.

Depending on the connection

– A 24-40 mm dia. hose clip may also be required for connecting the siphon (available from 

specialist retailers) 

a

page 4:

Water connection.

 Useful tool

– Spirit level for aligning the washing machine.

Water drainage

Elbow

for fixing the waste 
water hose

Aqua-Stop

Aqua-Secure

Standard

Power cord

Water supply

Covers

Hose holder

2

Hose and cable lengths 

depending on model

   

Installation area

– Stability is important to prevent the machine from wandering.
– The installation area must be firm and level.
– Soft floors/floor coverings such as e.g. carpets are not suitable. 

If installing the appliance on a wooden joist floor

– If possible, install the washing machine in a corner.
– Screw a water-resistant wooden panel (min. 30 mm thick) to the floor.
– It is 

essential 

to secure the washing machine feet with holding brackets*. 

*order no. WMZ 2200, WX 9756

Connection on left side

or

Connection on right side

Note

: if hose holders are used, the hose lengths may be reduced. 

Available from dealer/customer service:
– Aqua-Stop extension hose**, approx. 2.50 m.
– Longer supply hose, approx. 2.20 m, for standard model. 

**order no. WMZ 2380, WZ 10130

Built-under/Built-in appliance

Build-under/build-in before connection to the power supply.

Installed in between kitchen units (built-under or built-in)

– 60 cm cavity width required.
– Install washing machine only under a continuous worktop that is connected firmly to the 

adjacent cupboards.

~

135 cm

m

a

x

1

0

0

 c

m

~

100 cm

~

95 cm

~

140 cm

~

160 cm

~

165 cm

a

Содержание WLM20460BY

Страница 1: ...m 165 cm 3 Removing transport bolts Before using the appliance for the first time always remove and retain all 4 transport bolts If transporting the appliance subsequently always re install the transport bolts this prevents damage to the machine a page 6 Retain the screw and spacer 1 Take the hoses depending on the model out of the holder and the elbow Remove the elbow 2 Undo and remove all 4 tran...

Страница 2: ...pply 5 Remove the hoses Installing transport bolts 1 Remove the covers 2 Insert all 4 spacer Clamp the power cord into the holders Insert and tighten the screws The transport bolts must be removed after transportation a page 3 To prevent unused detergent from flowing into the outlet during the next wash Pour 1 litre of water into dispenser II and start the Drain or Spin programme Technical specifi...

Страница 3: ...ailers a page 4 Water connection Useful tool Spirit level for aligning the washing machine Water drainage Elbow for fixing the waste water hose Aqua Stop Aqua Secure Standard Power cord Water supply Covers Hose holder 2 Hose and cable lengths depending on model Installation area Stability is important to prevent the machine from wandering The installation area must be firm and level Soft floors fl...

Страница 4: ...y a technician Water supply Water inlet hose Attention do not kink crush modify or cut through strength is no longer guaranteed Optimum water pressure in the mains 100 1000 kPa 1 10 bar When the tap is turned on the water flow is at least 8 l min If the water pressure is higher install a pressure reducing valve Model Aqua Stop Aqua Secure Standard 1 Connect the water supply hose to the tap Tighten...

Страница 5: ...ultiple plugs connectors or extension cables ʑ If a residual current operated circuit breaker is used use only a type which features this symbol Only this symbol guarantees compliance with the currently valid regulations ʑ Mains plug do not insert into pull out of the socket with damp hands do not pull the plug out of the socket by pulling on the power cord never pull out the plug while the applia...

Страница 6: ...ective supply lines or fittings up to the Aqua Stop connection on the tap 4 Appliances which feature Aqua Stop can be left unattended during operation and it is not necessary to turn off the tap afterwards The tap should only be turned off if you are away for a prolonged period e g several weeks holiday Installation instructions Contents Page ʋ Safety instructions 1 ʋ Environmental disposal 1 ʋ Sc...