2.2 UTMC OTU SOFTWARE VERSIONS AND COMPATIBILITY
The UTMC OTU (16MB RAM) software package is 667/TZ/32370/000*. The software
requires a CPU card fitted with 16MB SD RAM i.e. CPU 667/1/26608/999 issue 9 or
later. This package incorporates MOVA 6.
*For MOVA 7 software package 667/TZ/32378/000 should be used, this also requires
16MB of SD RAM.
The UTMC OTU (4MB RAM) software package is 667/TZ/32369/000. Older Gemini
2
CPU cards, issue 8 or earlier, can run this software. This is a reduced version which
does not support MOVA or full UTC (UTC type 2).
The UTMC OTU software will not run on the Gemini-1 processor card, due to memory
constraints.
The outstation software package part number and issue state can be displayed as
follows:-
On the web interface, view the “system” web screen
On the handset/telnet interface, use the ‘version` command
The latest releases of software can be obtained from the Siemens website, currently at
http://www.siemens.co.uk/traffic/en/index/downloads.htm
. Details of the upgrade
procedure are included in the download .zip file.
2.2.1 Controller Compatibility
The UTMC OTU supports the semi-integral interface to ST700/750/800/900 family
controllers running compatible firmware as follows:-
Controller Firmware
Compatible
Versions
PB800
24 or later
PB801
all
The UTMC OTU supports serial interface connection for remote handset access to the
following controllers.
Peek TRX
Peek TSP
Peek PTC-1
TSEU Sentinel
Serial interface connection to other controllers may operate successfully, provided that
the baud rate is supported and the controller operates a standard ASCII terminal
(command line) interface.