background image

Installation Instructions 
Document No. 540-149 
September 2, 2008 

Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as 
design improvements are introduced. TALON is a registered trademark of Siemens Building Technologies, Inc. Other product or company names 
mentioned herein may be the trademarks of their respective owners. © 2008 Siemens Building Technologies, Inc. 

 

Siemens Building Technologies, Inc.  

1000 Deerfield Parkway 
Buffalo Grove, IL  60089-4513 
U.S.A. 

Your feedback is important to us. If you have 
comments about this document, please send them to

 

[email protected]

 

 

Document No. 540-149 
Country of Origin:  U.S. 

Page 4

 

of 4

 

Accessories 

Review Table 1 to verify that you have the appropriate mounting hardware.  

For retrofit installations, normally follow the method used by the pre-existing device. You may need to replace existing 
mounting hardware. Always mount the sensor vertically. 

Table 1.  Mounting Accessories. 

P/N Description 

Used 

For 

Reference 

182-621E  Gym Guard Kit, satin 

chrome 

gyms and similar environments requiring a guard. 
(Incompatible with adapter bases and the extender 
ring.) 

155-222P25 
(TB 193) 

182-683 

Metal (and Wood) Stud 
Mounting Bracket (pkg. 5) 

Single-sensor rough-in installations. Kit includes 
locator. 

129-057 

182-685 Spring 

Clips: 

Finished 

Drywall Mounting Kit  
(10 pack) 

Drywall mounting. 

129-073 

192-506 

Electrical Box Adapter Plate 
Assembly Kit (pkg. 5) 

Electrical boxes mounted flush with the wall and for 
gyms and similar environments requiring a guard. 
(Also see 

544-782

.) 

Figure 5 

192-860 

Finish Plate Kit 1 Gang 1 
Sensor; stainless steel 

Single-sensor, low-cost mounting. Plate is 3.7 × 5.1 
inches (9.5 × 12.9 cm) 

155-252P25 
(TB 238) 

536-666 Mounting 

Strap 

Standard 

light switch plate (field-supplied) to mount 

sensor on 2 × 4 electrical box 

540-040 
540-237 

544-782B  Single Adapter Base 

Mounting Kit, white 

2 × 4 boxes, all single sensor installations on walls 
with oversized holes, paint lines, etc., that need to be 
covered, and on exterior brick/cement-type walls. Kit 
includes Electrical Box Adapter Plate Assembly 
(192-495. Adapter base is 3-1/2 × 5 inches 
(8.8 × 12.7 cm). 

Figure 5 

544-783B  Double Adapter Base 

Mounting Kit, white 

4 × 6 boxes and all double sensor installations on 
walls with oversized holes, paint lines, etc., that need 
to be covered, and on exterior brick/cement-type 
walls. Kit includes two mounting plates (192-720). 
Adapter base is 5 × 7 inches (12.7 × 18 cm). 

Figure 5 

544-784 

Non-conduit Rough-in Kit, 
Double 

Double-sensor non-conduit rough-in installations. Kit 
includes locator. 

540-784 

544-785B  Extender Ring Kit, white 

Exterior brick or cement-type walls; fits to back of 
sensor base plate 

— 

544-800 

Universal Adapter Kit 

Retrofitting a previous horizontal installation to a 
vertical one, or when the screw spacing does not fit 
the electrical box adapter plate. Kit includes multi-
slotted adapter plate. 

Figure 5 

981-344 

Electrical Box Cover Plate 
Kit 

2 × 4 box rough-ins. Kit includes locator and 
connector. 

— 

 

Содержание TALON

Страница 1: ...2B BACnet Digital Room Temperature Sensor with fan switch white Warning Caution Notations CAUTION Equipment damage or loss of data may occur if you do not follow a procedure as specified Required Tools Phillips sizes 1 and 2 screwdrivers Medium flat blade screwdriver Small flat blade screwdriver Medium duty electric drill 3 16 inch 4 8 mm drill bit 1 inch 25 mm hole saw Small level Tape measure Ma...

Страница 2: ...or base plate as a template See Figure 2 CAUTION For drywall mounting only use the top and bottom holes TH0703R1 3 16 4 8 1 25 4 1 3 8 34 9 1 25 4 2 3 8 60 3 Figure 2 Mounting and Center Hole Locations Dimensions in Inches Millimeters 2 Drill two 3 16 inch 4 8 mm mounting holes 3 Cut a one inch 25 mm center hole with a hole saw 4 If using screws to attach the sensor insert two plastic wall anchors...

Страница 3: ...erature Sensor RTS port on the controller Connect the fan switch cables wires to the appropriate controller terminal The installation is now complete Electrical Box and Rough in Mounting Typical 1 If a locator is attached to the rough in device remove the locator by removing the two screws and lightly rocking the locator to pull it free 2 Untie the twist tie and pull about three inches 75 mm of th...

Страница 4: ...nting 129 073 192 506 Electrical Box Adapter Plate Assembly Kit pkg 5 Electrical boxes mounted flush with the wall and for gyms and similar environments requiring a guard Also see 544 782 Figure 5 192 860 Finish Plate Kit 1 Gang 1 Sensor stainless steel Single sensor low cost mounting Plate is 3 7 5 1 inches 9 5 12 9 cm 155 252P25 TB 238 536 666 Mounting Strap Standard light switch plate field sup...