Troubleshooting
aus
45
Fault
Cause
Troubleshooting
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
Water tap is jammed or
furred up.
▶
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
1.
Switch off the appliance.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
5.
Remove the filter from the supply
hose
6.
Clean the filter.
7.
Re-insert the filter in the supply
hose.
8.
Screw the water connection back
on.
9.
Check the water connection for
leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
E:92-40 will light up altern-
ately.
Filters are soiled or blocked.
▶
Clean the filters.
E:61-03 will light up altern-
ately. Water is not drained.
Wastewater hose is blocked
or kinked.
1.
Reposition the wastewater hose
without kinks.
2.
Remove residues.
Siphon connection is still
sealed.
▶
Check the connection to the siphon
and open if necessary.
Cover of the wastewater
pump is loose.
▶
Secure the cover of the "Wastewa-
ter pump "
into position.
E:61-02 will light up altern-
ately.
Wastewater pump is
blocked.
▶
Clean the wastewater pump.