Revision 09/04
Elastomer bearing
Document No.: A5E00353789B
Page 18
6. Setting the overload protection:
•
Load the loading platform with the
maximum applicable load.
•
Set the overload protection
mechanism (7) in connection with the
nut (6) to 0.05 - 0,1 mm, see
dimension X in Fig. 2-3
•
Dimension X must exist after
tightening the nut (6) as well.
DANGER
Contaminated, icy or incorrectly set overload protection will create blockages
which cause incorrect measurements or can cause injury or damage to the
machinery by overloading the scale.
2.3 Technical Data
2.3.1 Function Data
Rated load
0.5 t - 5 t
Permitted transverse movement
± 4 mm
Fig. 2-3 Setting the overload
protection