SITRANS P measuring instruments for pressure
Transmitters for hydrostatic level
MPS series (submersible sensor)
2/148
Siemens FI 01 · 2009
2
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
■
Dimensional drawings
SITRANS P pressure transmitters, MPS series, dimensions in mm (inch)
Junction box, dimensions in mm (inch)
Cable hanger, dimensions in mm (inch)
Selection and Ordering data
Order No.
SITRANS P pressure transmitters
for pressure, MPS series (submers-
ible sensor)
C)
7 M F 1 5 7 0 -
7 7
A 0
7 7 7 7
2-wire system
Note: Junction box and cable hanger
included in delivery
Cable material
PE
}
1
FEP
5
Measuring range Cable length L
0 ... 2 mH
2
O
10 m
}
C
0 ... 4 mH
2
O
10 m
}
D
0 ... 5 mH
2
O
25 m
}
B
0 ... 6 mH
2
O
25 m
}
E
0 ... 10 mH
2
O
25 m
}
F
0 ... 20 mH
2
O
25 m
}
G
0 ... 6 ftH
2
O
32 ft
K
0 ... 12 ftH
2
O
32 ft
L
0 ... 18 ftH
2
O
82 ft
M
0 ... 30 ftH
2
O
82 ft
N
0 ... 60 ftH
2
O
82 ft
P
Special measuring range/Special cable
length
1)
Specify measuring range and cable
length in plain text
1)
Special measuring ranges between 0 ... 1 mH
2
O (0 ... 3 ftH
2
O)
and 0 ... 200 mH
2
O (0 ... 656 ftH
2
O) and special cable lengths up to
1000 m (3281ft) are possible. With Ex versions the max.
special cable length is 50 m (150 ft). The length of free-hanging cable
should not exceed 375 m.
Z
J 1 Y
Explosion protection
• without
}
1
• with, type of protection "Intrinsic safe-
ty" (Ex II 1 G EEx ia IIC T4)
}
2
• With approval for drinking water to
WRAS and ACS
}
D)
6
Further designs
Order code
Quality inspection certificate (Factory
calibration) to IEC 60770-2, add "-Z" to
Order No. and Order code.
C11
Order No.
Quality inspection certificate (Factory
calibration) to IEC 60770-2 supplied
later, specify factory no. of transmitter
for this porpose.
7MF1564-8CC11
Accessories (as spare parts)
Junction box
7MF1570-8AA
for connecting the transmitter cable
Cable hanger
7MF1570-8AB
for mounting the pressure transmitter
}
Available ex stock
Power supply units
see "SITRANS I power supply units and input isola-
tors".
+
(br
o
w
n
)
-
(blue)
S
c
ree
n
V
e
nt p
i
p
e
Pr
ot
e
ct
i
v
e
c
a
p
158
(6
.
2)
L
Ø
27
(1
.
1
diam
.
)
Cable
s
hea
t
h
8
.3
(
0.33
)
diam
.
(bla
c
k
o
r
blue
,
PE/HFFR)
Flexible
c
able
wi
t
h
0.
5
mm
2
(
0.000
78
i
nc
h
2
)
c
r
oss
-
s
e
ct
i
on
V
e
nt p
i
p
e
1
(
0.0
4)
diam
.
(i
nn
er
diame
t
er)
Pr
ot
e
ct
i
v
e
c
a
p
wi
t
h
4
x
3
diam
.
(4
x
0.
12
diam
.
)
h
o
le
s
(bla
c
k
,
PA)
Cable
s
hea
t
h
S
t
re
n
g
t
h
co
rd
(whi
t
e)
Venting
valve
57 (2.25)
Mounting
hole
50 (1.97)
79 (3.1)
30
(1.2)
94 (3.7)
65 (2.56)
M20x1.5
22
(0.87)
M20x1.5
22
(0.87)
30
(1.2)
© Siemens AG 2008