7MF4232
Operating Instructions
18
C79000-B5676-C92-01
Total of
230 to 500
Ω
HART
R
-
Communicator
HART
R
-Modem
or:
or:
+ HK --
SITRANS P
transmitter
Hazardous
location
Non-hazardous lo-
cation
7NG4021
U
H
Figure 2.5 Electrical connection with power supply isolator for Smart transmitter
2.3
Installing the analog indicator
- Unscrew the housing cover of the terminal side (marked ”FIELD TERMINALS” on the housing)
- Plug analog indicator into the test sockets
Depending on the operating position of the transmitter the analog indicator can be plugged in two
different positions (rotation by
180
_
possible).
- Screw in casing cover with glass pane
2.4
Turning the digital indicator
- Unscrew housing cover of the electronics side
- Unscrew digital indicator
- Plug in the digital indicator
Depending on the operating position of the transmitter the digital indicator can be plugged in four
different positions (rotation by
90
_
or
180
_
possible).
- Screw on digital indicator
- Screw in housing cover