Installing/Mounting
4.5 Potential equalization
22
Figure 4-11 Cathodic protection
●
Isolate the sensor from cathodic protected pipes using insulated bolts.
●
Use bypass cable between the mating flanges
NOTICE
Remote mounted sensor versions
If the above is not acceptable, remote mounted sensors can alternatively be connected
as follows:
Connect coil current cable shield at sensor end via a 1.5 µF condensator
Make sure that electrode cable shield is not connected at both ends