SITRANS LU180
Operating Instructions, 06/2016, A5E37100674-AA
35
Troubleshooting
7
The echo is not reliable and the LU180 is waiting for a valid echo
before updating the measurement.
Probable causes are:
•
Material or object in contact with sensor face
•
The LU180 is too close to the fill point
•
The LU180 is not perpendicular to the liquid surface
•
Change in level too fast
•
Measurement out of range
•
Foam on liquid surface
•
High level of vibration in the mounting structure
•
Level inside the blanking zone
The 'Waiting' period has expired. Investigate the probable caus-
es listed above.
Refer to Speed of response (Page 30) or Fail-safe timer
(Page 33) for duration of 'Waiting' periods.