A5E32106122
SITRANS LR260 (HART) – QUICK START MANUAL
Page EN-7
m
mmmm
Englis
h
Connecting HART
Typical PLC/mA configuration with HART
Wiring setups for hazardous area installations
1. Intrinsically Safe wiring
• For power demands see
Loop Voltage versus Loop Resistance
on page 19.
• For wiring requirements: follow local regulations.
• Approved dust-tight and water-tight conduit seals are required for outdoor NEMA 4X /
type 4X / NEMA 6, IP67, IP68 locations.
• Refer to
Instructions specific to hazardous area installations
on page 9.
active PLC
HART modem
SITRANS LR260
power
supply
Notes:
• Depending on the system
design, the power supply may
be separate from the PLC, or
integral to it.
• Loop resistance (total of cable
resistance plus 250 Ohm
[resistor]) must be less than
550 Ohm for the device to
function properly.
R= 250
HART
communicator
SITRANS LR260
Siemens Milltronics Process Instruments, Peterborough
7MLxxxx-xxxxx-xxxx-
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: – 40°C to 80°C
Power Rating: 24 V
Max., 4 - 20 mA
Nom., 30 V
Serial No: GYZ / S1034567
HART
Ui = 30 V
Ii = 120 mA
Pi = 0.8 W
Ci = 15 nF
Li = 0.1 mH
0518
0891
BOX 1
Assembled in Canada with domestic and imported parts
KCC-REM-S49
SITRANSLR
1/2 D
II 1 G D,
, 2 D
Ex ia IIC T4 Ga
Ex ta IIIC T100°C Da
SIRA 11ATEX2348X
IECEx SIR 11.0153x
ARP0108 Ex ia IIC T4 Ga
WARNING: Use Cable Rated >100°C
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA – VEJA INSTRUÇÕES
- UTILIZAR CABOS ADEQUADOS PARA TEMPERATURAS >100 °C
Ex ia IIC T4 Ga
Ex ta IIIC T 100°C Da
DNV 12.0081 X
OCP 0017
The ATEX certificate listed on the nameplate
can be downloaded from the product page of our website at: www.siemens.com/LR260. Go
to Support > Approvals / Certificates.
The IECEx certificate listed on the nameplate can be viewed on the IECEx website. Go to:
http://iecex.iec.ch and click on Ex Equipment Certificates of Conformity then enter the
certificate number IECEx SIR 11.0153X.
Device nameplate (ATEX/IECEX/INMETRO/C-TICK)
FM/CSA Intrinsically Safe connection drawing number A5E03745229 can be downloaded
from the product page of our website at: www.siemens.com/LR260. Go to Support >
Installation Drawings > Level Measurement > Continuous - Radar.
Device nameplate (FM/CSA)
Содержание SITRANS LR260
Страница 1: ...SITRANS Radar Transmitters SITRANS L 260 HART R Quick Start Manual 12 2013 ...
Страница 2: ......
Страница 22: ...Page EN 20 SITRANS LR260 HART QUICK START MANUAL A5E32106122 mmmmm English Notes ...
Страница 42: ...Side DA 20 SITRANS LR260 HART KVIKSTART MANUAL A5E32106122 mmmmm Dansk Notater ...
Страница 62: ...Seite DE 20 SITRANS LR260 HART KURZANLEITUNG A5E32106122 mmmmm Deutsch Notizen ...
Страница 82: ...Σελίδα EL 20 SITRANS LR260 HART ΠΕΡΙΛΗΠΤΙΚΟ ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ A5E32106122 mmmmm Ελληνικά Σημειώσεις ...
Страница 102: ...Página ES 20 SITRANS LR260 HART PUESTA EN MARCHA RÁPIDA A5E32106122 mmmmm Español Notas ...
Страница 122: ...Page FR 20 SITRANS LR260 HART MISE EN SERVICE RAPIDE A5E32106122 mmmmm Français Notes ...
Страница 142: ...Pagina IT 20 SITRANS LR260 HART MANUALE DI AVVIO RAPIDO A5E32106122 mmmmm Italiano Annotazioni ...
Страница 162: ...Pagina NL 20 SITRANS LR260 HART QUICK START HANDLEIDING A5E32106122 mmmmm Nederlands Opmerkingen ...
Страница 182: ...Página PT 20 SITRANS LR260 HART MANUAL DE INÍCIO RÁPIDO A5E32106122 mmmmm Português Observações ...
Страница 202: ...Sivu FI 20 SITRANS LR260 HART PIKAKÄYTTÖOPAS A5E32106122 mmmmm Suomi Huomautukset ...
Страница 222: ...Sida SV 20 SITRANS LR260 HART SNABBSTARTSMANUAL A5E32106122 mmmmm Svenska Anmärkningar ...