Valves and pumps
Precautions
Avoid installation at the highest point in the
system because air bubbles will be trapped in
the flowmeter.
Avoid installation at a point where there is a
free outlet after the flowmeter.
The flowmeter pipe section may be installed
in either a horizontal or vertical position.
Note
To obtain
maximum
battery lifetime with the
Lithium Thionyl Chloride battery pack,
Siemens recommends installing the flowmeter
transmitter in an upright position.
3 x 90° bends in two planes
L2: Min. 20 x pipe diameter
L1: 3 x pipe diameter
Valves
L2: Min. 10 x pipe diameter, fully open valve
L1: 3 x pipe diameter
Pumps:
L2: Min. 20 x pipe diameter
L1: 3 x pipe diameter
Triple bend