9.2.1

Pipe dimensions for FUS380 and FUE380

Transmitter IP67/NEMA 4X/6, wall mounting

9.2

Dimensional drawings for FUS380 and FUE380

Size

PN 16

PN 25

PN 40

L

Weight

L

Weight

L

Weight

A1

D

D1

Lift

DN

mm

kg

mm

kg

mm

kg

mm

mm

mm

hug

50

-

-

300 +0-2

10

350

165

125

No

65

-

-

300 +0-2

15

360

185

145

No

80

-

-

350 +0-2

18

370

200

160

No

100

350+0-2

15

-

-

350+0-3

18

375

220

180

No

125

350+0-2

18

-

-

350+0-3

24

380

250

210

No

150

500+0-3

28

-

-

500+0-3

34

390

285

240

Yes

200

500+0-3

38

500+0-3

47

500+0-3

55

414

340

295

Yes

250

600+0-3

60

600+0-3

76

600+0-3

91

440

405

355

Yes

300

500+0-3

66

500+0-3

81

-

-

466

460

410

Yes

350

550+0-3

94

550+0-3

121

-

-

495

520

470

Yes

400

550+0-3

124

550+0-3

153

-

-

507

580

525

Yes

500

625+0-3

190

625+0-3

244

-

-

558

715

650

Yes

600

750+0-3

303

750+0-3

365

-

-

609

840

770

Yes

700

875+0-3

361

875+0-3

552

-

-

660

910

840

Yes

800

1000+0-3

494

1000+0-3

770

-

-

710

1025

950

Yes

900

1230 +/-6

475

1300 +/-6

835

-

810

1125

1050

Yes

1000

1300 +/-6

594

1370 +/-6

1078

-

910

1255

1170

Yes

1200

1360 +/-6

732

-

-

1110

1485

1390

Yes

Notes:

Weight for transmitter/electronics 1.5 kg (3.3 lb).

• D and D1 are values for standard versions (with standard flanges).

For versions with higher pressure ratings - see EN 1092-1.

• - Means not available.

Содержание SITRANS FUE380

Страница 1: ...c flowmeter type SITRANS FUS380 Ultrasonic flowmeter type SITRANS FUE380 type approved for heat metering s Technical Documentation handbooks instructions manuals etc for the complete product range SITRANS F can be found on the internet intranet via the following link English http www4 ad siemens de WW view en 10806951 133300 ...

Страница 2: ...2 SFIDK PS 022 Q5 02 Introduction 1 General safety instructions 2 Description 3 Installation 4 Electrical connection 5 Operation 6 Troubleshooting 7 Sealing 8 Technical data 9 Ordering 10 Appendix 11 ...

Страница 3: ...ng diagram base of connection board 13 5 Electrical connection 14 5 1 Pulse output A and B setting 14 5 1 1 FUE380 preset pulse output A settings dedicated to energy calculator type SITRANS FUE950 14 5 1 2 FUS380 and FUE380 preset output B settings 15 5 1 3 Wiring diagram for connection to energy calculator type SITRANS FUE950 16 6 Operation 17 6 1 Flowmeter operation via key and display 17 6 2 Op...

Страница 4: ...sing the equipment Only personnel authorized and trained by the owner of the equipment may operate the equipment Installation personnel must ensure that the measuring system is correctly connected in accordance with the connection diagram For applications involving high working pressures or media that can be dangerous to people surroundings equipmentorotherintheeventofpipefracture Siemensrecommend...

Страница 5: ...safety standard They may however present a potential hazard if they are abused electrically or mechanically This is in most circumstances associated with the generation of excessive heat where increased internal pressure may cause the cell to rupture Thus the following basic precautions should be observed when handling and using lithium batteries Do not short circuit recharge overcharge or connect...

Страница 6: ...emtypeFUS380orFUE380 ForFUS380aspare part transmitter can be ordered separate see FI01 catalogue For FUE380 is this not allowed according the approvals For both systems the sensor part cannot be ordered without a transmitter In FUS380 parameters and pulse output are preset from factory and protected via software lock A software tool is required to change parameters In FUE380 metrological parameter...

Страница 7: ...e and after the flowmeter Furthermore a minimum distance between flowmeter and pumps and valves must be respected It is also important to centre the flowmeter in relation to flanges and gaskets Make sure that the flowmeter is positioned as low as possible to prevent air from being trapped in the flowmeter at the transducers Find a position on the pipeline where the inlet pipe to the flowmeter has ...

Страница 8: ...er pipe section may be installed in either a horizontal or vertical position Note To obtain maximum battery lifetime with the Lithium Thionyl Chloride battery pack Siemensrecommendsinstallingtheflowmeter transmitter in an upright position 3 x 90 bends in two planes L2 Min 20 x pipe diameter L1 3 x pipe diameter Valves L2 Min 10 x pipe diameter fully open valve L1 3 x pipe diameter Pumps L2 Min 20 ...

Страница 9: ...transfer to the transmitter The recommendation applies to both battery powered and mains powered versions 4 2 3 Mains powered version The mains powered version can always be retrofitted with a battery pack In the event of power failure the battery will take over the power supply of the unit The battery is not of a rechargeable type The battery must be replaced every 6 years At delivery the transmi...

Страница 10: ...uration and numbers of mains power failures the battery has a lifetime of minimum 6 years one battery Average one mains power failure per day duration 1 hour for min 6 years Check that the mains power supply symbol appears in the display when installation is complete This symbol indicates that installation is correct If the mains power supply connection is not established correctly the flowmeter w...

Страница 11: ...rt the battery pack Connect the small plug in between the two main connectors Ensure that the wire is inserted into the small channel leading from plug to battery Note Siemens recommends replacing the battery every 5 6 years Every time a battery is fitted and connected the unit runs a start up routine see section Operation Changing the battery does not influence the accumulated value Accumulated v...

Страница 12: ...ly push the cables one by one from underneath the base through the glands and adjust all four cable ends approximately 100 mm from the upper frame of the base see figure 4 4 1 Installation of wall pipe bracket 1 Loosen the 2 screws on each side of the unit and remove the transmitter 2 Mount the wall bracket in an appropriate place taking the coaxial cable length into con sideration and allowing ad...

Страница 13: ...nection board 4 4 3 Transducer connection scheme Cables 1A and 1B first track 1A upstream 1B downstream Cables 2A and 2B second track 2A upstream 2B downstream Note Do not change the length of the four cables as this will influence the accuracy of the unit ...

Страница 14: ...S380 FUE380 Output A Forward reverse Preset Forward Output B Preset Alarm Preset Alarm Output B function Reverse pulse alarm call up Preset Alarm Pulse value A B 0 1 l p 0 25 l p 0 5 l p 1 l p 2 5 l p Preset See scheme to FUE380 depenting on DN value 10 l p 25 l p 50 l p 100 l p 250 l p 500 l p 1 m3 p 2 5 m3 p Settings typically for 5 m3 p 10 m3 p 25 m3 p SITRANS FUE950 energy 50 m3 p 100 m3 p cal...

Страница 15: ...riangle alert appears on the display The failure code F1 appears in display menu 4 and the relay output terminals switch to off Fig 1 Call up indication see Fig 2 The call up output is active until manually reset by use of PDM program The call up function is also activated when alarm output function is activated SIMATIC PDM Process Device Manager see accessories spare parts in catalogue FI01 Fig 2...

Страница 16: ...RANS FUE950 and SITRANS FUE380 20 meter Important Pulse output from the flowmeter must correspond to pulse input setting on the energy calculator 5 1 3 Wiring diagram for connection to energy calculator type SITRANS FUE950 Connection to energy calculator SITRANS FUE950 ...

Страница 17: ... When the internal counter is reset the battery symbol will indicate full Press the key within 6 seconds The message accept will appear the internal counter will be reset and the battery indicator will show full see Fig 1 The transmitter control panel is designed with a single key and a digital display for optimal dialog see Fig 2 and Fig 3 Key Activate the key to toggle to the next index and rela...

Страница 18: ...de indicates a specific failure Menu 1 Flow volume totalizer 1 Battery icon shows full Menu 2 FUS380 only Flow volume totalizer 2 factory configured for reverse flow Negativevaluesindicatereverseflowcalculation Menu 3 Actual flow rate Negative values indicate reverse flow Display test Check of all segments Display toggles between all segments on off 6 2 Operator menu Failure code combinations F12i...

Страница 19: ...ion in display F12 This indicates a combination of failure codes F1 and F2 Diagnosis No water in pipe or track 1 and 2 cables defect or transducers defect Troubleshooting 7 7 1 Alarm code There are two symbols for battery charge status The battery full symbol indicates the battery charge is above the warning level 6 year hour counter The batterylow symbolindicatesthatthebattery charge is below the...

Страница 20: ...ling of the SITRANS FUE380 Sensor DN 100 1200 8 2 Verification sealing of the SITRANS FUE380 Verfication sealing bottom of transmitter Transmittter older sealing Transmitter Verfication sealing under frame Transmittter new sealing Sensor DN 50 80 ...

Страница 21: ... Preset to pulse output for forward flow Pulse output B Preset to alarm for present failure Pulse width 5 10 20 50 100 200 500 ms Max pulse frequency 100 Hz Volume units FUE380 m3 FUS380 Preset at ordering default Flow units FUE380 m3 h default FUS380 Preset at ordering Alarm codes Track 1 2 measuring internal failure battery low flow overload pulse output frequency overload Cable length Max 30 me...

Страница 22: ...5 414 340 295 Yes 250 600 0 3 60 600 0 3 76 600 0 3 91 440 405 355 Yes 300 500 0 3 66 500 0 3 81 466 460 410 Yes 350 550 0 3 94 550 0 3 121 495 520 470 Yes 400 550 0 3 124 550 0 3 153 507 580 525 Yes 500 625 0 3 190 625 0 3 244 558 715 650 Yes 600 750 0 3 303 750 0 3 365 609 840 770 Yes 700 875 0 3 361 875 0 3 552 660 910 840 Yes 800 1000 0 3 494 1000 0 3 770 710 1025 950 Yes 900 1230 6 475 1300 6...

Страница 23: ...2 19 68 0 0 12 146 19 68 0 0 12 179 18 35 18 11 16 14 Yes 14 21 65 0 0 12 207 21 65 0 0 12 267 19 8 20 8 18 8 Yes 16 21 65 0 0 12 273 21 65 0 0 12 337 19 96 22 83 20 67 Yes 20 24 61 0 3 419 24 61 0 3 538 21 97 28 15 25 59 Yes 24 29 53 0 0 12 668 29 53 0 0 12 805 23 98 33 07 30 31 Yes 28 34 45 0 0 12 796 34 45 0 0 12 1217 25 98 35 83 33 07 Yes 32 39 37 0 0 12 1089 39 37 0 0 12 1698 27 95 40 35 37 4...

Страница 24: ...version G no battery included 3 Pulse width setup 5 ms standard 2 10 ms 3 20 ms 4 50 ms 5 100 ms 6 200 ms 7 500 ms 8 Order No Order code Flowmeter SITRANS FUS380 7ME 3 4 0 0 standard 0 A max flow range Diameter Qp m3 h Qs m3 h DN 50 2 1 15 15 1 A DN 50 2 1 15 45 1 C DN 50 2 1 30 45 1 D DN 65 2 1 25 25 1 E DN 65 2 1 25 75 1 G DN 65 2 1 50 72 1 H DN 80 3 1 40 40 1 J DN 80 3 1 40 120 1 L DN 80 3 1 40...

Страница 25: ...ers add plain text Y17 Self adhesive plastic tag with 8 mm characters max 15 characters add plain text Y18 For accessories and spare parts see end of following chapter to FUE380 MLFB Ordering example Customer requires a flowmeter DN 250 PN 25 compact version media temperature max 120 C mains power version Material certificate and metal tag name plate Pulse output for 10 l pulse and min 5 ms puls w...

Страница 26: ...0003 25200 5 V Order No Order code Flowmeter SITRANS FUE380 7ME 3 4 1 0 type approved Flange norm and pressure rating EN 1092 1 PN 16 DN 100 1200 C PN 25 DN 200 1000 D PN 40 DN 50 250 4 E Compact remote connection Compact version max 120 C 248 F 0 Remote version max 200 C 392 F 5 m 16 4 ft 2 10 m 32 8 ft 3 20 m 65 6 ft 4 30 m 98 4 ft 5 Approvals pulse output Without approval neutral 0 Selectable p...

Страница 27: ...approved according to EN 1434 verified and sealed for Germany Material certificate and metal tag name plate Pulse output for energymeter SITRANS FUE950 Ordering FUE380 7ME3410 2LD05 4DG2 Z F10 Y17 Example of appropriate energy meter Energy meter type FUE950 03110 0R1CB 10300 DK2 00012 Order No Order code Flowmeter SITRANS FUE380 7ME 3 4 1 0 type approved Country approved type 6 Neutral no approval...

Страница 28: ...otocol 5 m 16 4 ft cable set 4 pcs for DN 50 80 remote mounting A5E01208092 10 m 32 8 ft cable set 4 pcs for DN 50 80 remote mounting A5E01208114 20 m 65 6 ft cable set 4 pcs for DN 50 80 remote mounting A5E01208117 30 m 98 4 ft cable set 4 pcs for DN 50 80 remote mounting A5E01208121 1 m 3 28 ft cable set 4 pcs for DN 50 80 compact version A5E01208126 5 m 16 4 ft cable set 4 pcs for DN 100 1200 r...

Страница 29: ...量计 质量流量计 超声波流量计 温度变送器 压力变送器 阀门定位器 气体分析仪等 三 德国 UWT 公司的阻旋式料位开关 音叉式料位开关 重锤式料位计等产品 四 自行研发生产超声波液位计 温度变送器 压力变送器 数显表及油田专用仪器等产品 成立于 1954 年的西门子 妙声力公司 Milltronics 是世界公认的超声波物位测量领域 的领导者 全球最大的超声波物位仪表生产厂家 在超声波 雷达 电容技术领域拥有超过 60 项专利 超声波产品的综合性能指标经美国 控制 杂志评比 其综合性能名列全球第一 作为西门子公司长期稳定的代理商 我公司有着 10 余年产品的销售和服务经验 无论 从专业技术水平 现货及备件库存量 售后服务质量 仪表维护以及故障产品国内维修能力 等方面 都具备显著的优势 尤其是我公司一流的技术支持和高效率高品质的服务体系 在 业界具有很高的知名度 如果您需要相关的产品 需要...

Отзывы: