Procedure   

1. Crimp the cable lug onto the protective conductor.
2. Screw the cable lug onto the protective conductor connection as shown.

3. Tighten the M4 screw with a torque of 1.5 Nm.
4. Wire the protective conductor to the protective conductor connection of the control cabinet 

in which the device is installed.

8.6

Connecting the terminal

The terminal for connecting the power supply to interface X80 is attached to the device. The 

terminal is designed for conductors with a cross-section of 0.25 mm² to 2.5 mm². Only connect 

conductors with a cross-section ≥0.5 mm².
You can use either semi-rigid or flexible cables. You do not need to use end sleeves.

Requirement

● 1 connection terminal
● 0.5 × 3 mm flat-tip screwdriver

Connecting

8.6 Connecting the terminal

MCU 1720

Equipment Manual, 09/2019, A5E47437728B AB

63

Содержание SINUMERIK MCU1720

Страница 1: ... MC 09 2019 A5E47437728B AB Preface 1 System overview 2 Fundamental safety instructions 3 Description 4 Application planning 5 Dimension drawings 6 Installation 7 Connecting 8 Service and maintenance 9 Technical specifications 10 Spare parts accessories 11 Safety symbols 12 Appendix A ...

Страница 2: ... are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are use...

Страница 3: ... 4 2 1 Overview of operating and display elements 26 4 2 2 LED displays 27 4 2 3 Start up and mode selector switch 30 4 3 Interfaces 31 4 4 Type plates 32 5 Application planning 35 5 1 Supplementary electrical conditions 35 5 1 1 Grounding concept 35 5 1 2 RI suppression measures 35 5 1 3 EMC limit values in South Korea 36 5 2 Climatic and mechanical environmental conditions 37 5 2 1 Shipping and ...

Страница 4: ...64 8 8 Power supply X80 65 8 8 1 Properties 65 8 8 2 Connecting the power supply 68 8 8 3 Requirements for the power supply 69 8 9 Use of Ethernet interfaces 71 8 10 PROFINET 72 8 11 Digital inputs outputs 74 8 11 1 DIO application 74 8 11 2 Block diagram 76 8 11 3 Connecting digital inputs outputs 76 8 11 4 Technical data 78 8 12 CFast 79 8 13 DisplayPort 79 8 14 USB 80 8 15 SD card 81 8 15 1 Pro...

Страница 5: ...and removing the backup battery 91 11 2 Installing and removing CFast cards 93 12 Safety symbols 95 A Appendix 97 A 1 Abbreviations 97 A 2 MC documentation overview 100 Index 101 Table of contents MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 5 ...

Страница 6: ...Table of contents MCU 1720 6 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 7: ... mail to the following address mailto docu motioncontrol siemens com mySupport Documentation At the following address https support industry siemens com My ww en documentation you can find information on how to create your own individual documentation based on Siemens content and adapt it for your own machine documentation Training At the following address http www siemens com sitrain you can find...

Страница 8: ...l manufacturer are documented by the machine tool manufacturer Other functions not described in this documentation might be executable in the control This does not however represent an obligation to supply such functions with a new delivery or when servicing Further for the sake of simplicity this documentation does not contain all detailed information about all types of the product and cannot cov...

Страница 9: ...ea If you have any technical questions use the online form in the Support Request area EC Declaration of Conformity The EC Declaration of Conformity for the EMC Directive can be found on the Internet at the following address https support industry siemens com cs https support industry siemens com cs ww de ps 14604 certww en ps 13231 cert Preface MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 9 ...

Страница 10: ...Preface MCU 1720 10 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 11: ...aining costs smaller spare parts inventories and fewer interfaces The SMC functionality of the S7 1500 is used for example for positioning or speed axes as well as the CNC functionality of SINUMERIK for machining tasks Customized user interfaces WinCC Net can be created based on the open windows based HMI configuration Integrated safety functions for man and machine based on the fail safe S7 1500 ...

Страница 12: ...omponents Up to 2 OPs Operator Panels can be operated on one MCU The following components can be connected to the MCU SINUMERIK operator panel front and machine control panel Distributed PLC I O SIMATIC e g ET200SP and ET200MP SINUMERIK via PROFINET IO SINUMERIK I O modules PP 72 48D PN and PP 72 48D 2 2A PN SINAMICS S120 and SINAMICS S210 drive systems Feed motors main spindle motors and direct d...

Страница 13: ...OFINET functionality PROFINET I O for PLC peripherals PROFINET I O for NCK peripherals isochronous PLC isochronous drives MC technology objects PLC non isochronous drives Basic positioner function module Closed loop position control function module NCK isochronous and non isochronous drives also with Safety Integrated PROFIsafe V2 Note Precondition TIA Portal as of V15 System overview 2 2 System c...

Страница 14: ...lashDrive 16 GB USB 3 0 6ES7648 0DC60 0AA0 Table 2 2 Order data for mounting sets spare parts accessories Mounting sets spare parts accessories Article number Mounting rail brackets for rail mounting 6ES7648 1AA20 0YM1 Mounting bracket for portrait mounting 6ES7648 1AA20 0YP0 Ordering options The described products can be found in the following catalogs All the devices that belong to the SINUMERIK...

Страница 15: ...f the power connections and the protective conductor connection 5 Check whether the existing auxiliary supply circuits are de energized 6 Ensure that the motors cannot move 7 Identify all other dangerous energy sources e g compressed air hydraulic systems or water Switch the energy sources to a safe state 8 Check that the correct drive system is completely locked After you have completed the work ...

Страница 16: ...ck if there is no ground connection For missing or incorrectly implemented protective conductor connection for devices with protection class I high voltages can be present at open exposed parts which when touched can result in death or severe injury Ground the device in compliance with the applicable regulations WARNING Spread of fire from built in devices In the event of fire outbreak the enclosu...

Страница 17: ...imum clearance as ventilation clearance for the respective component NOTICE Overheating due to inadmissible mounting position The device may overheat and therefore be damaged if mounted in an inadmissible position Only operate the device in admissible mounting positions WARNING Unexpected movement of machines caused by inactive safety functions Inactive or non adapted safety functions can trigger ...

Страница 18: ...ts modules and devices when you are grounded by one of the following methods Wearing an ESD wrist strap Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring Only place electronic components modules or devices on conductive surfaces table with ESD surface conductive ESD foam ESD packaging ESD transport container 3 3 Warranty and liability for application examples Applicat...

Страница 19: ...ls and or network segmentation are in place For additional information on industrial security measures that can be implemented please visit Industrial security https www siemens com industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they become available and that only the ...

Страница 20: ...curity concept for the installation or machine Make sure that you include all installed products into the holistic industrial security concept Protect files stored on exchangeable storage media from malicious software by with suitable protection measures e g virus scanners On completion of commissioning check all security related settings Protect the drive against unauthorized changes by activatin...

Страница 21: ...articles gases etc can occur inside and outside the components under fault conditions caused by for example Component failure Software errors Operation and or environmental conditions outside the specification External influences damage 3 Hazardous shock voltages caused by for example Component failure Influence during electrostatic charging Induction of voltages in moving motors Operation and or ...

Страница 22: ...Fundamental safety instructions 3 5 Residual risks of power drive systems MCU 1720 22 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 23: ...om simple positioning tasks up to complex multi axis systems The following elements characterize an MCU Battery backed real time clock Slot for an SD Card Interfaces for operation Ethernet interfaces PROFINET interfaces Digital inputs outputs 6 of which can be parameterized as inputs for probes and BERO Commissioning interfaces Ethernet interface MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 2...

Страница 24: ... X80 24 V DC 15 20 max 5 A X142 X152 24 V DC 15 20 max 2 A Axes Max 8 CNC axes SIMATIC S7 Motion Control technology objects up to max 2400 resources SINAMICS EPOS axes in regards to I O addresses and performance Drives Max 8 drives for CNC axes Max 20 drives controlled by SIMATIC S7 Motion Control technology objects Channels 4 Mode groups BAG 1 Drives and storage media SSD solid state disk 2 5 240...

Страница 25: ...tion for program execution Restart can be parameterized in the event of a fault Alarm messages can be analyzed by the application program local via LAN LED display 4 LEDs to display system states of which 3 can be freely programmed by the user Software Operating system Windows 10 IoT Enterprise LTSB 2016 64 bit Description 4 1 Characteristics MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 25 ...

Страница 26: ... DIAG LED display of the PLC RUN ERR MT LED display of the HMIs PC ON WD RUN STOP ERR MT and user LEDs L1 L2 L3 On off switch The on off switch does not isolate the device from the power supply Position ON when the _ symbol is pressed When delivered it is in the OFF position Figure 4 1 Position of operator control and display elements Description 4 2 Operator control and display elements MCU 1720 ...

Страница 27: ...ng state LED flashes green Communication possible no configuration LED lights up yellow CP was stopped via PLC TIA No communication LED flashes yellow Configuration received and transition to the RUN operating state LED flashes red Error status FATAL error DIAG Diagnostics LED lights up green Everything OK LED lights up yellow Software related fault is pending e g at PLC HMI Linux Gener ate the di...

Страница 28: ... short interval Active force job PROFIenergy pause LED lights up green LED off LED flashes yellow A plant maintenance requirement is pending The affected hardware must be validated replaced within a foreseeable interval Configuration faulty LED lights up yellow LED off LED flashes yellow Firmware update completed successfully LED lights up yellow LED off LED off CPU is in STOP operating state LED ...

Страница 29: ...e control program e g WinAC You can find program examples to control LEDs under the Windows operating systems at the Customer Support page Industry Automation and Drive Technologies https support industry siemens com cs start lc en WW Important LED states If all the LEDs are flashing the PLC must be reset general reset via the mode selector switch ramp up with the switch in the MRES position While...

Страница 30: ...ommissioning switch The PLC mode selector switch Setting during normal operation Run RUN Places the PLC in the RUN operating state STOP Places the PLC in the STOP operating state MRES Initiates the PLC reset Figure 4 3 PLC mode selector switch Further information You can find further information at CNC Commissioning Manual Part 1 NCK PLC drive Description 4 2 Operator control and display elements ...

Страница 31: ...74 X127 P1 Ethernet Page 71 X130 P1 X150 P1 PROFINET Page 72 X150 P2 X160 P1 X125 X135 2x USB 3 0 Page 80 X140 Service socket1 X155 SD card Page 81 X1 P1 Ethernet PN IE Page 72 X2 P1 X3 P1 X3 is not available X70 X71 DisplayPort connections for digital monitors Page 79 X50 Slot for the CFast card with cover Page 79 X60 X63 4x USB 3 0 Page 80 Description 4 3 Interfaces MCU 1720 Equipment Manual 09 ...

Страница 32: ...onnect a display 4 4 Type plates Nameplate on the front The following figure shows information contained on the nameplate 20 3 07 55 581 581 6723 05 6 5 5 72 86 5 0 18 1 5 1 3 55 581 6723 3 21 07 9 352 1 7 1 0 3 9 0 3 5 3 5 3 86 6 86 33 DVW 3 20 20 3 3 33 3 Figure 4 5 Nameplate on the front Description 4 4 Type plates MCU 1720 32 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 33: ...id of the Siemens Industry Online Support App to be taken directly to the Internet Webpage for the product including all of the technical information and graphical data The app is available for iPhone iPad Android and Windows Phone Note The contents of the individual nameplate fields on the actual MCU may differ from those described in this Manual e g updated product status approvals and markings ...

Страница 34: ...ntent open the file with a text editor e g the Windows Editor application The file content can be displayed with any text editor on every standard computer system that supports the file system of the SD card See also Identification data of the device Page 48 Description 4 4 Type plates MCU 1720 34 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 35: ...or connection to the protective conductor Example Operator panel on the swivel arm In this case it is sufficient to connect the protective conductor connectors of e g SINUMERIK MCU and SIMATIC Panel for SINUMERIK to one another by a cable and to lead a common protective conductor to the central protective conductor connector in the control cabinet Further information You can find further informati...

Страница 36: ... is to be observed between the signal lines and power cables If necessary signal and load cables may cross one another if possible at an angle of 90 but must never be laid close or parallel to one another Only use cables approved by Siemens for the signal lines to and from the MCU Signal cables may not be routed close to strong external magnetic fields e g motors and transformers If signal lines c...

Страница 37: ...cording to EN 61800 2 with regard to shipping and storage conditions The following data applies under the following conditions Long term storage in the transport and product packaging At weather protected locations that have continuous contact with outside air through openings Transport in the transport packaging In unventilated containers under conditions not protected from weather effects In the...

Страница 38: ...ncrease in altitude derating Gradient Max 10 C h Relative humidity with out condensation 5 to 80 Condensation icing drip spray and splash water Not permitted Max installation alti tude Up to 4 000 m 13 123 ft above sea level Air pressure 689 1080 hPa Biological chemical and mechanical influences pollutants Biological environmental conditions Class 3B1 according to EN 60 721 3 3 Mold mold growth sl...

Страница 39: ... should be paid to cabling Please contact your sales representative for assistance and support Note In a residential environment this product can cause high frequency interference which may make interference suppression measures necessary Have qualified personnel carry out the installation and commissioning with appropriate radio interference suppression measures See also Designs Page 50 Applicati...

Страница 40: ...Application planning 5 2 Climatic and mechanical environmental conditions MCU 1720 40 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 41: ...Dimension drawings 6 6 1 Basic version Figure 6 1 MCU 1720 dimension drawing dimensions in mm MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 41 ...

Страница 42: ...ing Figure 6 2 Dimension drawings of the attachment to DIN rail of the MCU 1720 horizontal mounting position dimensions in mm Dimension drawings 6 2 DIN rail mounting MCU 1720 42 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 43: ...ounting Figure 6 3 Dimension drawings of the portrait mounting of the MCU 1720 vertical mounting position dimensions in mm Dimension drawings 6 3 Portrait mounting MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 43 ...

Страница 44: ...Dimension drawings 6 3 Portrait mounting MCU 1720 44 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 45: ...ure conforming to UL 61800 5 1 is therefore a mandatory requirement for approval or operation in accordance with UL 61800 5 1 Open equipment These modules are open equipment This means they may only be installed in housings cabinets or in electrical service rooms that can be entered or accessed exclusively by means of a key or tool Housings cabinets or electrical equipment rooms may only be access...

Страница 46: ...deep 4 x anchors 6 mm 40 mm long 4 x screws 4 mm 40 mm long Anchor 8 mm 40 mm long Screw 5 mm 40 mm long Plasterboard min 13 mm thick 14 mm Toggle bolt 4 mm 50 mm long Control cabinet installation Please refer to the SINAMICS documentation for more details WARNING Risk of fire through overheating if there are insufficient ventilation clearances Inadequate ventilation clearances cause overheating w...

Страница 47: ... original packaging in case you have to transport the unit again Note Damage to the device during transport and storage If a device is transported or stored without packaging shocks vibrations pressure and moisture may impact the unprotected unit Damaged packaging indicates that ambient conditions have already had a massive impact on the device and it may be damaged This may cause the device machi...

Страница 48: ...n Moisture causes a short circuit in electrical circuits and damages the device In order to prevent damage to the device proceed as follows Store the device in a dry place Bring the device to room temperature before starting it up Do not expose the device to direct heat radiation from a heating device If condensation develops wait approximately 12 hours or until the device is completely dry before...

Страница 49: ...ched to the side of the device when a Windows operating system is installed The Windows 10 COA label has an additional security feature which conceals part of the product key The scratch off panel consists of a small transparent label with a silver colored scratch coating which was applied to conceal part of the 25 character product key This scratch off panel is designed to protect the product key...

Страница 50: ...east 50 mm For a vertical mounting position and portrait mounting Below at least 50 mm Above at least 50 mm Laterally at least 50 mm Horizontal mounting attachment to DIN rail The interfaces point downward During operation different temperature ranges are permissible depending on the mounting position You can find information on this in the section Operating conditions Page 38 Installation 7 2 Pre...

Страница 51: ...ket Before you can install the device on a DIN rail you will need to attach the DIN rail clip to the device The fasteners and screws required are supplied with the device for the selected mounting option as specified in order number Requirement 1 DIN rail clip 4 screws 1 T20 screwdriver Installation 7 3 DIN rail mounting MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 51 ...

Страница 52: ...tandard profile The DIN rail is installed at the installation site Note Ensure that the wall or ceiling can bear four times the total weight of the device including the standard mounting rail See Safety instructions Page 45 Installation 7 3 DIN rail mounting MCU 1720 52 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 53: ... the rail The device engages with an audible click Removal 1 Push down the device until it is released by the rail clips 2 Swing the device out of the standard profile rail 3 Lift the device up and off 7 4 Upright mounting The fasteners and screws required are supplied with the device for the selected mounting option as specified in order number Installation 7 4 Upright mounting MCU 1720 Equipment...

Страница 54: ...with three screws 7 5 Mounting strain reliefs The scope of delivery for the device includes strain reliefs for the Ethernet PROFINET and DP connections Requirement 2 strain reliefs 5 screws 1 T10 screwdriver Installation 7 5 Mounting strain reliefs MCU 1720 54 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 55: ...k screws 2 Tighten the strain reliefs Use the countersunk head screws included with the strain reliefs Removal Follow the steps for installation in reverse order Installation 7 5 Mounting strain reliefs MCU 1720 Equipment Manual 09 2019 A5E47437728B AB 55 ...

Страница 56: ...Installation 7 5 Mounting strain reliefs MCU 1720 56 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 57: ...ion cables and jump to a person Death serious injury and burns can be caused by lightning Take the following precautions Disconnect the device from the power supply in good time when a thunderstorm is approaching Do not touch mains cables and data transmission cables during a thunderstorm Keep a sufficient distance from electric cables distributors systems etc NOTICE Fault caused by I O devices Th...

Страница 58: ...he system and the MCU must be disconnected brought into a no voltage condition 8 2 Overview Connection options The MCU has a series of interfaces via which the power supply and the remaining system components are connected The various SINAMICS components are connected with the MCU via PROFINET Actuators and sensors can be connected to the digital inputs outputs The MCUs have the following communic...

Страница 59: ... SIMATIC PROFINET I O devices SD card LQGRZV 1 8 3 3RZHU VXSSO 3RZHU VXSSO SINUMERIK MCP 398C incl EM 66 EM 131 and EM 187 SINUMERIK electr handwheel SINAMICS S120 CU3x0 2 PN SINAMICS S210 SINUMERIK MCU 1720 PROFINET Ethernet USB Ethernet PN IE X80 X127 P1 X130 P1 X150 P1 X150 P2 X160 P1 X142 X152 X60 X61 X62 X63 USB X125 X135 DisplayPort X70 X71 X50 X1 P1 X2 P1 Service X155 X140 Figure 8 1 Option...

Страница 60: ...etwork X2 port 1 Factory network X70 X71 DisplayPort socket DP V1 2 DP Connection of the operator panel fronts for use under Win dows X60 X61 X62 X63 2x Double SuperSpeed type A socket USB devices for Windows X50 CFast standard slot CFast Card Windows X80 2 pole screw type terminal 24 V DC power supply for computing unit 1 The X140 interface is designed for service purposes only and cannot be used...

Страница 61: ...ted network con nection with a remote device X1302 102 TCP S7 communication ISO on TCP according to RFC 1006 SIMATIC S7 1500 PLC communication X1302 4840 TCP UDP OPC UA Protocol OPC UA Unified Architecture is a standardized industrial communication protocol for access to con trol data e g by higher level control systems X1302 5900 TCP UDP VNC Virtual Network Computing VNC is a software that displa...

Страница 62: ... The protective conductor discharges dangerous currents tripping an overcurrent protection switch The protective conductor also improves the discharge of interference generated by external power cables signal cables or cables for I O devices to ground Requirement The device has been installed 1 protective conductor minimum cross section 2 5 mm2 1 T20 screwdriver 1 x M4 cable lug Connecting 8 5 Con...

Страница 63: ...installed 8 6 Connecting the terminal The terminal for connecting the power supply to interface X80 is attached to the device The terminal is designed for conductors with a cross section of 0 25 mm to 2 5 mm Only connect conductors with a cross section 0 5 mm You can use either semi rigid or flexible cables You do not need to use end sleeves Requirement 1 connection terminal 0 5 3 mm flat tip scre...

Страница 64: ...ewdriver on the connection terminal and the socket can damage the device Connect the wires to the connection terminal when it is not plugged in 8 7 Connecting peripheral equipment Note Observe suitability for industrial applications Only connect I O devices that are suitable for industrial applications in accordance with EN IEC 61800 3 Note I O devices capable of hot plugging USB Hot plug I O devi...

Страница 65: ...e booting to ensure it is correctly detected and run by the BIOS and the operating system The screen may otherwise remain dark Note The connected or built in I Os should not introduce a counter emf into the device A counter e m f greater than 0 5 V to ground on the 3 3 V DC 5 V DC 12 V DC due to a connected or integrated component can prevent normal operation or even destroy the computer When meas...

Страница 66: ...be crushed or pinched Route all of the cables so that they cannot come into contact with chafing edges Les câbles de raccordement doivent répondre aux conditions suivantes Le câble 24 V CC doit être autorisé pour des températures jusqu à 75 C Choisir la section de conducteur conformément aux prescriptions nationales NEC VDE dans le tableau ci dessous Interface X124 Le courant de sortie de l alimen...

Страница 67: ...e maximum possible short circuit current of the power supply unit used Table 8 2 X80 interface Characteristics Version Connector type 2 pole screw type terminal Number of cables that can be connected 1 Connectable cable types and conductor cross sec tions Rigid 1 3 mm 2 5 mm Flexible 1 3 mm 2 5 mm Flexible with end sleeve without plastic sleeve 1 3 mm 2 5 mm Flexible with end sleeve with plastic s...

Страница 68: ... Note The device may only be connected to a 24 volt power supply which meets the requirements of a protective extra low voltage PELV according to IEC UL 61800 5 1 The device has electrical reverse polarity protection Requirement The device has been installed The protective conductor is connected 1 wired terminal The corresponding 24 V DC power supply is off 1 0 5 3 Philips screwdriver Connecting 8...

Страница 69: ...ication Interface Typ current consumption 1 Max current consumption 2 X80 4 A 5 A X142 X152 2 A 2 A 1 MCU only processor memory etc 2 MCU with full load at all outputs digital outputs USB etc Note Inrush current To start the device requires an inrush current of at least 6 5 A for 15 ms The peak value of the starting current depends on the input voltage and the impedance of the 24 V DC power supply...

Страница 70: ...or EMC reasons this connection should only be made at one point This connection is normally provided as standard in the S7 1500 I Os In exceptional circumstances when this is not the case the ground connection should be made on the grounding rail of the control cabinet please also refer to EMC EMC Installation Guide Table 8 4 DC power supply requirements according to EN 61131 2 Rated voltage 24 VD...

Страница 71: ...iagnostic purposes the RJ45 sockets are each equipped with a green and an orange LED This allows the following status information about the respective Ethernet port to be displayed Table 8 5 Assignment of Ethernet interfaces X1 P1 X2 P1 X3 P1 X127 P1 and X130 P1 in the 1 GBit s mode Connector Pin Name Type Remark 1 DA B Bidirectional pair A 2 DA Bidirectional pair A 3 DB Bidirectional pair B 4 DC ...

Страница 72: ... Max data transmission rate 10 100 1000 Mbit s Max cable length 100 m 8 10 PROFINET Application Via the PROFINET interface you can establish PROFINET IO communications networks between the PLC of the control and the field devices X150 P1 and P2 support IRT X160 supports RT Properties The PROFINET interfaces are separate interfaces The PROFINET interface X150 is equipped with an integrated 2 port s...

Страница 73: ...range Activity Flashes Data exchange Off No data exchange Signal type O Output I Input Table 8 7 Assignment of PROFINET interface X160 in the 10 100 MBit s mode Connector Pin Name Type Remark 1 DA B Bidirectional pair A 2 DA Bidirectional pair A 3 DB Bidirectional pair B 4 DC Bidirectional pair C 5 DC Bidirectional pair C 6 DB Bidirectional pair B 7 DD Bidirectional pair D 8 DD Bidirectional pair ...

Страница 74: ...l I O are used Digital inputs isolated Digital outputs electrically isolated Bidirectional digital inputs outputs only for drive terminals The assignment of I Os to functions can be parameterized freely by the user The enable signals for the drive units and or motors Line Module Motor Module connected to the MCU can be switched using the digital inputs Note Terminal assignments When commissioning ...

Страница 75: ...ut GND reference potential ground Table 8 10 X152 digital inputs outputs Pin Signal name Signal type Meaning 1 P24EXT VI 24 V power supply for DIOs 2 NC IO4 O Dig NC output electrically isolated 3 NC IO5 O Dig NC output electrically isolated 4 MEXT GND Ground for DIOs electrically isolated 5 NC IO6 O Dig NC output electrically isolated 6 NC IO7 O Dig NC output electrically isolated 7 MEXT GND Grou...

Страница 76: ...for digital inputs outputs 8 11 3 Connecting digital inputs outputs Cable specification Table 8 11 Cable specification for X142 X152 Characteristics Version Connector type 2x 7 pole Micro Combicon grid Number of cables that can be connected 1 Connection option 0 2 to 1 5 mm2 Max current carrying capacity 6 A Max cable length 30 m Connecting 8 11 Digital inputs outputs MCU 1720 76 Equipment Manual ...

Страница 77: ...ke R Series UL Category ZMVV Wiring digital inputs outputs 1 Strip 10 mm of insulation from the wires 2 Wire the digital inputs of the interface for connection of the sensors 3 Wire the digital outputs of the interface for connection of the actuators 4 Insert the cable into the corresponding terminal Using shielded cables Note Use the shielded cable at interfaces X142 X152 1 Attach the cable shiel...

Страница 78: ...f X142 X152 Parameters Values Voltage 24 VDC Maximum load current per output 625 mA continuously short circuit proof Output delay typ max 1 L H 50 μs 150 μs H L 75 μs 150 μs Switching frequency for resistive load max 100 Hz for inductive load max 1 Hz for lamp load max 11 Hz max lamp load 5 W 1 Data for Vcc 24 V load 48 Ω High 90 Vout Low 10 Vout Note Ensuring the function of the digital inputs An...

Страница 79: ... PC7 GND Device GND PC8 LED1 LED Output not connected PC9 LED2 LED Output not connected PC10 IO1 Reserved Input Output not connected PC11 IO2 Reserved Input Output not connected PC12 IO3 Reserved Input Output not connected PC13 PWR Device Power 3 3V PC14 PWR Device Power 3 3V PC15 GND Device GND PC16 GND Device GND PC17 CDO Card Detect Out 8 13 DisplayPort Pin Short name Meaning Input output 1 ML_...

Страница 80: ...ble 8 15 Cable specification for the interfaces X60 and X61 X62 and X63 X125 and X135 X60 and X61 X62 and X63 X125 and X135 Connector type Double USB socket type A Double USB socket type A Double USB socket type A Version USB 3 0 USB 3 0 USB 3 0 Current carrying capacity 1 A 1 A 1 A Max cable length 3 m 3 m 3 m Max power consumption of all interfaces 15 W Note The 5 V power supply is designed to b...

Страница 81: ...ot with designation SD X155 interface NOTICE Inserting or withdrawing with the power connected can destroy the SD card The SD card may be inserted or removed only when the system is de energized Data The SD card is required to operate the MCU As well as the base software for SINUMERIK the SD Card also contains User data programs configuration data parameter settings Version info serial number vers...

Страница 82: ...und terminal before touching the SD card Please proceed as follows 1 Switch off the power supply 2 Gently insert the SD card into the plug in slot until it clicks into place 3 Switch the power supply on again Connecting 8 15 SD card MCU 1720 82 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 83: ...ts or abrasive cleaners Note Avoid damage Do not clean the device using compressed air or steam jets because they can damage it Checking the device In order to prevent foreign bodies or liquids entering the device regularly check the device for the following Ensure that all the housing screws are in place and tight For damage to the housing For damage to the cable cover or cable entry Protect the ...

Страница 84: ...t maintained Deviating connector assignment Please contact your technical customer service The device is not op erational There is no power supply to the device Check if the power switch is set to ON The monitor remains dark The monitor is switched off Switch on the monitor The monitor is in power save mode Press any key on the keyboard The brightness button has been set to dark Set the monitor br...

Страница 85: ... mouse pointer still does not appear on the screen after you have performed these checks and measures please contact your technical support team Wrong time and or date on the PC Press ESC during the booting process to open the BIOS Setup Set the time and date in the setup menu USB device not re sponding Operating system does not support the USB port No remedy The operating system does not have a s...

Страница 86: ...Service and maintenance 9 1 Troubleshooting MCU 1720 86 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 87: ...t tenu de veiller à ce que les exigences en matière de résistance à l incendie du matériel selon UL 94 V 1 et les exigences en matière de stabilité mécanique protection incendie protection contre les contacts selon UL 61800 5 1 soit remplies par la mise en œuvre d une enveloppe anti incendie externe Note Our products for industrial applications are presently not in the area of validity of Directiv...

Страница 88: ...ass A Noise immunity with regard to con ducted interference on the supply cables 2 kV according to IEC 61000 4 4EN burst Noise immunity on signal cables 1 kV according to IEC 61000 4 4 burst length 3 m 2 kV according to IEC 61000 4 4 burst length 3 m Immunity to electrostatic discharge 6 kV contact discharge according to IEC 61000 4 2 8 kV air discharge according to IEC 61000 4 2 Immunity to high ...

Страница 89: ...he operator panels and the safety relevant accessories comply with the harmonized European standards EN promulgated in the Official Journals of the European Community 2004 108 EC Electromagnetic Compatibility EMC directive Directive 2006 42 EC of the European Parliament and Council of May 17 2006 on machinery and Directive 95 16 EC amendment China RoHS The products comply with the China RoHS direc...

Страница 90: ...Technical specifications 10 3 Recycling and disposal MCU 1720 90 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 91: ...stic garbage Users are legally obliged to return used batteries and rechargeable batteries It is a punishable offense if you do not correctly dispose of batteries and rechargeable batteries Observe the following when disposing of batteries and rechargeable batteries Dispose of individually used batteries and rechargeable batteries as special waste in accordance with local legal requirements You ca...

Страница 92: ... not recharge do not open do not short circuit do not reverse the polarity do not heat above 100 C and protect from direct sunlight moisture and condensation Removal NOTICE Date and time setting are lost The time setting is cleared if it takes more than 30 seconds to replace the battery The device time is no longer synchronized Timer controlled programs will no longer run or run at the incorrect t...

Страница 93: ...maged Requirement The device is switched off SIMATIC IPC CFast card that is approved for industrial applications Procedure Installation NOTICE Inserting a memory card If you are using the memory card in a device installed in a system you must observe the safety regulations for work on electrical systems Insert the CFast card into the slot working carefully and without applying excess force 1 Relea...

Страница 94: ...e and lock the cover Removal Remove the CFast card from the memory slot by pushing it in until it is ejected by about 5 mm Proceed in reverse order Spare parts accessories 11 2 Installing and removing CFast cards MCU 1720 94 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 95: ...l shock in the event of an error or for a connect ing terminal of the external protective conductor Ground To identify the functional grounding General warning symbol The documentation must be consulted in any scenario where the sym bol is affixed in order to find out the type of potential hazard and the actions required to avoid the risk Warning hot surface Caution ESD components sensitive to ele...

Страница 96: ...Safety symbols MCU 1720 96 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 97: ...t CRC Cyclic Redundancy Check checksum validation CRT Cathode ray tube CSA Canadian Standards Association CTS Clear To Send Clear To Send cULus UL Underwriters Laboratories tested for Canada and USA DC Direct Current DCD Data Carrier Detect Data carrier signal detection DCP Discovery and basic Configuration Protocol standard for assigning IP addresses DIN Deutsche Industrie Norm German Industry St...

Страница 98: ...s mode ISO International Standards Organization KC Korean Certification LAN Local Area Network LED Light Emitting Diode light emitting diode display LGPL Lesser General Public License MAC Media Access Control MC Motion control MCP Machine Control Panel MLFB Machine readable product designation MPP Machine Pushbutton Panel NAMUR Standardization association for instrumentation and control systems in...

Страница 99: ...ive Data SATA Serial Advanced Technology Attachment SD Secure Digital secure digital memory card SDRAM Synchronous DRAM SELV Safe Extra Low Voltage SIOS Siemens Industry Online Support SMC Standard Motion Control SME Sensor Module External SSD Solid State Drive SSH Secure Shell SW Software TCU Thin Client Unit communication with operator panels TCP Transmission Control Protocol TPM Trusted Platfor...

Страница 100: ... support industry siemens com cs ww en view 109771043 You can display documents or download them in PDF and HTML5 format The documentation is divided into the following categories User Operating User Programming Manufacturer Service Commissioning Manufacturer Service Functions Safety Integrated Appendix A 2 MC documentation overview MCU 1720 100 Equipment Manual 09 2019 A5E47437728B AB ...

Страница 101: ...supply 70 Diagnostics Ethernet 71 PROFINET 73 System 27 Troubleshooting 84 Digital inputs outputs Assignment 75 Technical data 78 Wiring 77 Wiring diagram 76 Dimensions 88 DisplayPort Interface 79 E Electromagnetic compatibility 88 Emitted interference 88 equipment 45 Equipotential bonding 35 63 Error messages Troubleshooting 84 Ethernet address 49 F FAQs 84 G Grounding measures 35 I Interface Dig...

Страница 102: ...ng 47 Packaging 47 Checking 47 Removing 47 PLC mode selector switch 30 Power consumption 88 Power supply 69 Connecting 69 Processor 88 PROFINET 13 Pin assignment 73 Protective conductor 62 Connecting 62 S Safety information Storage 48 Transportation 48 Scope of maintenance 83 Sensors 58 Shielding 35 Strain relief 51 T Troubleshooting FAQs 84 U USB 3 0 Interface 81 Index MCU 1720 102 Equipment Manu...

Отзывы: