4.2.3
Start-up and mode selector switch
The MCU is equipped with an NCK rotary coding switch and a PLC mode selector switch as a
toggle switch with three switch positions:
● The NCK commissioning switch:
Setting during normal operation: "0"
Figure 4-2
NCK commissioning switch
● The PLC mode selector switch:
Setting during normal operation: "Run"
RUN
Places the PLC in the RUN operating state.
STOP
Places the PLC in the STOP operating state.
MRES Initiates the PLC reset.
Figure 4-3
PLC mode selector switch
Further information
You can find further information at:
● CNC Commissioning Manual Part 1 (NCK, PLC, drive)
Description
4.2 Operator control and display elements
MCU 1720
30
Equipment Manual, 09/2019, A5E47437728B AB