Rotary switch: Feed override X30
Connector designation:
X30
Connector type:
2 x 5-pin plug connector, according to EN 60603-13 with coding
Max. cable length:
0.6 m
Table 1-15
Assignment of X30 connector (on delivery)
Pin
Name
Type
Meaning
1
N.C.
-
Not connected
2
N.C.
-
Not connected
3
M
V
Ground
4
N.C.
-
Not connected
5
P5
V
5 V supply
6
OV_VS16
I
Override rotary switch value 16
7
OV_VS8
Override rotary switch value 8
8
OV_VS4
Override rotary switch value 4
9
OV_VS2
Override rotary switch value 2
10
OV_VS1
Override rotary switch value 1
Rotary switch: Spindle override X31
Connector designation:
X31
Connector type:
2 x 5-pin plug connector, according to EN 60603-13 with coding
Max. cable length:
0.6 m
Table 1-16
Assignment of X31 connector (on delivery)
Pin
Name
Type
Meaning
1
N.C.
-
Not connected
2
N.C.
-
Not connected
3
M
V
Ground
4
N.C.
-
Not connected
5
P5
V
5 V supply
6
OV_SP16
I
Override rotary switch value 16
7
OV_SP8
Override rotary switch value 8
8
OV_SP4
Override rotary switch value 4
9
OV_SP2
Override rotary switch value 2
10
OV_SP1
Override rotary switch value 1
General information and networking
1.3 Connecting
Operator panel front: OP 010
30
Manual, 07/2018, A5E36371538B
Содержание SINUMERIK 840D sl OP 010
Страница 88: ...General information and networking 1 4 Networking Operator panel front OP 010 88 Manual 07 2018 A5E36371538B ...
Страница 90: ...Description Operator panel front OP 010 90 Manual 07 2018 A5E36371538B ...
Страница 104: ...Technical data Operator panel front OP 010 104 Manual 07 2018 A5E36371538B ...
Страница 110: ...Spare parts 7 2 Replacement Operator panel front OP 010 110 Manual 07 2018 A5E36371538B ...