Configuration 2: NCU and PCU with direct OP
Description
1&8
3&8
6\VWHPQHWZRUN
&RPSDQ\QHWZRUN
;
(WK
The NCU and PCU are connected via a crossed Ethernet cable.
The NCU is the DHCP server with the IP address 192.168.214.1.
For this Eth 2 configuration, the PCU is assigned a fixed IP address in the range
192.168.214.241 – 192.168.214.249 with a subnet mask 255.255.255.0 .
General information and networking
1.4 Networking
Operator panel front: OP 010
78
Manual, 07/2018, A5E36371538B
Содержание SINUMERIK 840D sl OP 010
Страница 88: ...General information and networking 1 4 Networking Operator panel front OP 010 88 Manual 07 2018 A5E36371538B ...
Страница 90: ...Description Operator panel front OP 010 90 Manual 07 2018 A5E36371538B ...
Страница 104: ...Technical data Operator panel front OP 010 104 Manual 07 2018 A5E36371538B ...