Emergency stop button
Rated voltage
24 VDC
Current rating, max.
3 A
Current rating, min.
1 mA
Switching capacity
DC 13 according to EN 60947-5-1
Conditional rated short-circuit current
10 A gL/gG according to EN 60947-5-1
B
10d
500000
Note
The quantitative assessment of the emergency stop safety function must be based on the
B
10d
values corresponding to the used standards (e.g. ISO 13849-1) under consideration of
the respective application (frequency of the actuation, service life, diagnostics by the evaluation
unit, etc.). The B
10d
values only apply when the technical properties of the emergency stop
button are taken into account.
9.1
Supplementary electrical conditions
9.1.1
Power supply
Requirements for DC power supplies
WARNING
Electric shock due to connection of an unsuitable power supply
When equipment is connected to an unsuitable power supply and/or insufficiently grounded
or rear cover (Page 35), exposed components may carry a hazardous voltage that might
result in serious injury or death.
● Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV
(Protective Extra Low Voltage) output voltages acc. to UL 61010 for all connections and
terminals of the electronics modules.
Technical data
9.1 Supplementary electrical conditions
Machine control panel: MCP 398C
Manual, 07/2018, A5E43199783B AB
57
Содержание SINUMERIK 840 sl
Страница 26: ...Description 2 4 Rating plate Machine control panel MCP 398C 26 Manual 07 2018 A5E43199783B AB ...
Страница 34: ...Dimension drawings Machine control panel MCP 398C 34 Manual 07 2018 A5E43199783B AB ...
Страница 51: ...3 4 5 6 Diagnostics 8 2 Output functions Machine control panel MCP 398C Manual 07 2018 A5E43199783B AB 51 ...
Страница 62: ...Technical data 9 3 Recycling and disposal Machine control panel MCP 398C 62 Manual 07 2018 A5E43199783B AB ...
Страница 66: ...Safety symbols Machine control panel MCP 398C 66 Manual 07 2018 A5E43199783B AB ...
Страница 68: ...Index Machine control panel MCP 398C 68 Manual 07 2018 A5E43199783B AB ...