If you upgrade SINUMERIK Operate from version 4.5.3 (or older) to version 4.5.4 (or later), you
must delete the existing service entries from the configuration file "systemconfiguration.ini"
manually.
The configuration file can be found in the following directories:
● Windows XP: F:\hmisl\user\sinumerik\hmi\cfg
● Windows 7: C:\Program Files (x86)\Siemens\MotionControl\user\sinumerik\hmi\cfg
● Linux: card/user/sinumerik/hmi/cfg
Procedure
1. Open the "systemconfiguration.ini" file.
2. Delete the following lines:
– SVC013 ...
– SVC014 ...
– SVC015 ...
– SVC017 ...
3. Save and close the file.
4. Delete the following files, if applicable:
– systemconfiguration.ini.453
– systemconfiguration.xml
7.1.6
Client update
7.1.6.1
Client update under Windows
Requirement
If not installed, install the PCU Base Software from 01.04.00.00 before starting the
SINUMERIK Integrate client update.
Procedure
1. Start the PCU in the Windows service mode.
2. Open the installation directory on the PCU.
Installing SINUMERIK Integrate
7.1 SINUMERIK Integrate with SINUMERIK Operate
Manage MyResources, Optimize MyProgramming /NX-Cam Editor
Installation Manual, 12/2019, A5E44672080B AE