Electrical connection
6.8 Final checks
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
86
Operating Instructions, 06/2018, A5E44455710A
6.8
Final checks
Before closing the terminal box/terminal base of the machine enclosure, check the following:
●
Establish the electrical connections in the terminal box in accordance with the information
in this documentation.
●
Maintain the air clearances between non-insulated parts as described in Chapter
Minimum air clearances. (Page 75)
●
Avoid protruding wire ends.
●
In order not to damage the cable insulation, freely arrange the connecting cables.
●
Connect the machine corresponding to the specified direction of rotation.
●
Keep the inside of the terminal box clean and free from trimmed-off ends of wire.
●
Ensure that all seals and sealing surfaces are undamaged and clean.
●
Correctly and professionally close unused openings in the terminal boxes. Observe the
information in this documentation.
●
Observe the information on torques in this documentation.
See also
Tightening torques for screw and bolt connections (Page 165)